Replacing a failed H610C or H615C chassis

You must replace a chassis to repair compute node failures related to the CPU, the motherboard, or if it does not power on. If your H610C compute node runs NetApp HCI Bootstrap OS version 1.6 or later, you can replace a failed DIMM and would not have to replace the chassis. For H615C, you need not replace the chassis if a DIMM fails; you need replace only the failed DIMM.

Before you begin

About this task

Alarms in the VMware vSphere Web Client alert you when a host fails. You must match the serial number of the failed host from the VMware vSphere Web Client with the serial number on the sticker at the back of the node.
Note: For H610C and H615C, the terms "node" and "chassis" are used interchangeably, because the node and chassis are not separate components.