NetApp E-Series data source

The NetApp E-Series data source collects inventory and performance information. There are two possible configurations (firmware 6.x and firmware 7.x+), and they both have the same values.

Terminology

OnCommand Insight acquires the following inventory information from the NetApp E-Series data source. For each asset type acquired by Insight, the most common terminology used for this asset is shown. When viewing or troubleshooting this data source, keep the following terminology in mind:

Vendor/Model Term Insight Term
Drive Disk
Volume Group Disk Group
Storage Array Storage
Controller Storage Node
Volume Group Storage Pool
Volume Volume
Note: These are common terminology mappings only and might not represent every case for this data source.

Requirements

Configuration

Field Description
Comma-separated list of Array SANtricity Controller IPs IP addresses and/or fully-qualified domain names for the array controllers

Advanced configuration

Field Description
Inventory Poll Interval (min) Interval between inventory polls (default 30 minutes)
Performance Poll Interval (up to 3600 seconds) Interval between performance polls (default 300 seconds)