Time synchronization

You might see issues with time synchronization in your grid.

Inaccurate NTP servers

If you encounter time synchronization problems, verify that you have specified at least four external NTP sources, each providing a Stratum 3 or better reference, and that all external NTP sources are operating normally and are accessible by your StorageGRID Webscale nodes.

Note: When specifying the external NTP source for a production-level StorageGRID Webscale installation, do not use the Windows Time (W32Time) service on a version of Windows earlier than Windows Server 2016. The time service on earlier versions of Windows is not sufficiently accurate and is not supported by Microsoft for use in high-accuracy environments, such as StorageGRID Webscale.

Support boundary to configure the Windows Time service for high-accuracy environments