Viewing status indicators and buttons on the SG6000-CN controller

The SG6000-CN controller includes indicators that help you determine the status of the controller, including the following indicators and buttons.


Front Indicators - SG6000-CN
  Display State Description
1 Power button Blue The controller is powered on.
Off The controller is powered off.
2 Reset button Not applicable Use this button to perform a hard reset of the controller.
3 Identify button Blinking blue

Identifies the controller in the cabinet or rack.

This button can be set to Blink, On (Solid), or Off.

Solid blue
Off The controller is not visually identifiable in the cabinet or rack.
4 Alarm LED Amber An error has occurred.
Note: To view the boot-up and error codes, you must access the BMC interface.
Off No errors are present.

General boot-up codes

During boot-up or after a hard reset of the SG6000-CN controller, the following occurs:
  1. The baseboard management controller (BMC) logs codes for the boot-up sequence, including any errors that occur.
  2. The power button lights up.
  3. If any errors occur during boot-up, the alarm LED lights up.

    To view the boot-up and error codes, you must access the BMC interface.