Complete power canister replacement

You complete the power canister replacement by confirming that the new power canister is working correctly. Then, you can gather support data and resume normal operations.

Steps

  1. On the new power canister, check that the green Power LED is on and the amber Attention LED is OFF.
  2. From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the problem has been resolved.
  3. If a failed power canister is still being reported, repeat the steps in Remove failed power canister and Install new power canister. If the problem continues to persist, contact technical support.
  4. Remove the antistatic protection.
  5. Collect support data for your storage array using SANtricity System Manager.
    1. Select Support > Support Center > Diagnostics.
    2. Select Collect Support Data.
    3. Click Collect.

    The file is saved in the Downloads folder for your browser with the name support-data.7z.

  6. Return the failed part to NetApp, as described in the RMA instructions shipped with the kit.

Result

Your power canister replacement is complete. You can resume normal operations.