Obtain the feature pack

To obtain the feature pack, you need the serial number from the controller shelf, a Feature Activation Code, and the Feature Enable Identifier for the storage array.

Steps

  1. Locate the serial number.
    1. From SANtricity System Manager, select Support > Support Center.
    2. With the Support Resources tab selected, scroll to the View top storage array properties section.
    3. Locate the Chassis Serial Number, and copy this value to a text file.


  2. Locate the feature pack submodel ID.
    1. From the SANtricity System Manager, select Support.
    2. Select the Support Center tile.
    3. On the Support Resources tab, locate and select the Storage Array Profile link.
    4. Type feature pack submodel ID in the text box, and click Find.
    5. Locate the feature pack submodel ID for the starting configuration.
  3. Using the feature pack submodel ID, locate the corresponding Controller submodel ID for the starting configuration and find the Feature Activation Code for the desired ending configuration within the table below. Then, copy that Feature Activation Code to a text file.
    Starting configuration Ending configuration Feature Activation Code
    Controller submodel ID Baseboard ports HIC ports Controller submodel ID Baseboard ports HIC ports
    318 FC FC 319 FC iSCSI ZGW-4L2-Z36IJ
    320 iSCSI FC 4GZ-NL2-Z4NRP
    321 iSCSI iSCSI TG2-7L2-Z5485
    no HIC or not an optical HIC 321 iSCSI no HIC or not an optical HIC TG2-7L2-Z5485
    319 FC iSCSI 318 FC FC 1G5-QL2-Z7LFC
    320 iSCSI FC FG7-AL2-Z82RW
    321 iSCSI iSCSI 5G7-0K2-Z0G8X
    320 iSCSI FC 318 FC FC 4GP-HL2-ZYRKP
    319 FC iSCSI PGU-KL2-Z1P7I
    321 iSCSI iSCSI BGA-8K2-ZQWM5
    321 iSCSI iSCSI 318 FC FC SGH-UK2-ZUCJG
    319 FC iSCSI 1GK-EK2-ZVSW1
    320 iSCSI FC AGM-XL2-ZWA8A
    no HIC or not an optical HIC 318 FC no HIC or not an optical HIC SGH-UK2-ZUCJG
    Starting configuration Ending configuration Feature Activation Code
    Controller submodel ID Baseboard ports HIC ports Controller submodel ID Baseboard ports HIC ports
    338 FC FC 339 FC iSCSI PGC-RK2-ZREUT
    340 iSCSI FC MGF-BK2-ZSU3Z
    341 iSCSI iSCSI NGR-1L2-ZZ8QC
    no HIC or not an optical HIC 341 iSCSI no HIC or not an optical HIC NGR-1L2-ZZ8QC
    339 FC iSCSI 338 FC FC DGT-7M2-ZKBMD
    340 iSCSI FC GGA-TL2-Z9J50
    341 iSCSI iSCSI WGC-DL2-ZBZIB
    340 iSCSI FC 338 FC FC 4GM-KM2-ZGWS1
    339 FC iSCSI PG0-4M2-ZHDZ6
    341 iSCSI iSCSI XGR-NM2-ZJUGR
    341 iSCSI iSCSI 338 FC FC 3GE-WL2-ZCHNY
    339 FC iSCSI FGH-HL2-ZDY3R
    340 iSCSI FC VGJ-1L2-ZFFEW
    no HIC or not an optical HIC 338 FC no HIC or not an optical HIC 3GE-WL2-ZCHNY
    Note: If your Controller submodel ID is not listed, contact NetApp Support.
  4. In System Manager, locate the Feature Enable Identifier.
    1. Go to Settings > System.
    2. Scroll down to Add-ons.
    3. Under Change Feature Pack, locate the Feature Enable Identifier.
    4. Copy and paste this 32-digit number to a text file.


  5. Go to NetApp License Activation: Storage Array Premium Feature Activation, and enter the information required to obtain the feature pack.
    • Chassis serial number
    • Feature Activation Code
    • Feature Enable Identifier
    Important: The Premium Feature Activation web site includes a link to “Premium Feature Activation Instructions.” Do not attempt to use those instructions for this procedure.
  6. Choose whether to receive the key file for the feature pack in an email or download it directly from the site.

After you finish