To obtain the feature pack, you need the serial number from the controller shelf, a Feature Activation Code, and the Feature Enable Identifier for the storage array.
Steps
- Locate the serial number.
- From SANtricity System Manager, select .
- With the Support Resources tab selected, scroll to the View top storage array properties section.
- Locate the Chassis Serial Number, and copy this value to a text file.
- Locate the feature pack submodel ID.
- From the SANtricity System Manager, select Support.
- Select the Support Center tile.
- On the Support Resources tab, locate and select the Storage Array Profile link.
- Type feature pack submodel ID in the text box, and click Find.
- Locate the feature pack submodel ID for the starting configuration.
- Using the feature pack submodel ID, locate the corresponding Controller submodel ID for the starting configuration and find the Feature Activation Code for the desired ending configuration within the table below. Then, copy that Feature Activation Code to a text file.
Note: Baseboard ports are disabled when running an NVMe protocol on the HIC.
Note: If you are not using the IB HIC, you can ignore the HIC Ports column in the following tables:
Table 1. Encryption Capable Feature Activation Codes (Baseboard Port Only Conversions)Starting Configuration |
Ending Configuration |
Feature Activation Code |
Controller submodel ID |
Ports to Convert |
Controller Submodel ID |
Ports Converted To |
360 |
FC baseboard ports |
362 |
iSCSI baseboard ports |
SGL-2SB-ZEX13 |
362 |
iSCSI baseboard ports |
360 |
FC baseboard ports |
5GI-4TB-ZW3HL |
Table 2. Encryption Capable Feature Activation CodesStarting configuration |
Ending configuration |
Feature Activation Code |
Controller Submodel ID |
Baseboard Ports |
HIC Ports |
Controller Submodel ID |
Baseboard Ports |
HIC Ports |
360 |
FC |
iSER |
361 |
FC |
SRP |
UGG-XSB-ZCZKU |
362 |
iSCSI |
iSER |
SGL-2SB-ZEX13 |
363 |
iSCSI |
SRP |
VGN-LTB-ZGFCT |
382 |
Not Available |
NVMe/IB |
KGI-ISB-ZDHQF |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
YGH-BHK-Z8EKB |
361 |
FC |
SRP |
360 |
FC |
iSER |
JGS-0TB-ZID1V |
362 |
iSCSI |
iSER |
UGX-RTB-ZLBPV |
363 |
iSCSI |
SRP |
2G1-BTB-ZMRYN |
382 |
Not Available |
NVMe/IB |
TGV-8TB-ZKTH6 |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
JGM-EIK-ZAC6Q |
362 |
iSCSI |
iSER |
360 |
FC |
iSER |
5GI-4TB-ZW3HL |
361 |
FC |
SRP |
EGL-NTB-ZXKQ4 |
363 |
iSCSI |
SRP |
HGP-QUB-Z1ICJ |
383 |
Not Available |
NVMe/IB |
BGS-AUB-Z2YNG |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
1GW-LIK-ZG9HN |
363 |
iSCSI |
SRP |
360 |
FC |
iSER |
SGU-TUB-Z3G2U |
361 |
FC |
SRP |
FGX-DUB-Z5WF7 |
362 |
iSCSI |
SRP |
LG3-GUB-Z7V17 |
383 |
Not Available |
NVMe/IB |
NG5-ZUB-Z8C8J |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
WG2-0IK-ZI75U |
382 |
Not Available |
NVMe/IB |
360 |
FC |
iSER |
QG6-ETB-ZPPPT |
361 |
FC |
SRP |
XG8-XTB-ZQ7XS |
362 |
iSCSI |
iSER |
SGB-HTB-ZS0AH |
363 |
iSCSI |
SRP |
TGD-1TB-ZT5TL |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
IGR-IIK-ZDBRB |
383 |
Not Available |
NVMe/IB |
360 |
FC |
iSER |
LG8-JUB-ZATLD |
361 |
FC |
SRP |
LGA-3UB-ZBAX1 |
362 |
iSCSI |
iSER |
NGF-7UB-ZE8KX |
363 |
iSCSI |
SRP |
3GI-QUB-ZFP1Y |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
5G7-RIK-ZL5PE |
403 |
Not Available |
NVMe/RoCE or NVMe/FC |
360 |
FC |
iSER |
BGC-UIK-Z03GR |
361 |
FC |
SRP |
LGF-EIK-ZPJRX |
362 |
iSCSI |
iSER |
PGJ-HIK-ZSIDZ |
363 |
iSCSI |
SRP |
1GM-1JK-ZTYQX |
382 |
Not Available |
NVMe/IB |
JGH-XIK-ZQ142 |
383 |
Not Available |
NVMe/IB |
PG0-KJK-ZUGW5 |
Table 3. Non-Encryption Feature Activation Codes (Baseboard Port Only Conversions)Starting configuration |
Ending Configuration |
Feature Activation Code |
Controller submodel ID |
Ports to Convert |
Controller Submodel ID |
Ports Converted To |
365 |
FC baseboard ports |
367 |
iSCSI baseboard ports |
BGU-GVB-ZM3KW |
367 |
iSCSI baseboard ports |
366 |
FC baseboard ports |
9GU-2WB-Z503D |
Table 4. Non-Encryption Feature Activation CodesStarting configuration |
Ending configuration |
Feature Activation Code |
Controller submodel ID |
Baseboard ports |
HIC ports |
Controller submodel ID |
Baseboard ports |
HIC ports |
365 |
FC |
iSER |
366 |
FC |
SRP |
BGP-DVB-ZJ4YC
|
367 |
iSCSI |
iSER |
BGU-GVB-ZM3KW |
368 |
iSCSI |
SRP |
4GX-ZVB-ZNJVD |
384 |
Not Available |
NVMe/IB |
TGS-WVB-ZKL9T |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
WGC-GJK-Z7PU2 |
366 |
FC |
SRP |
365 |
FC |
iSER |
WG2-3VB-ZQHLF |
367 |
iSCSI |
iSER |
QG7-6VB-ZSF8M |
368 |
iSCSI |
SRP |
PGA-PVB-ZUWMX |
384 |
Not Available |
NVMe/IB |
CG5-MVB-ZRYW1 |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
3GH-JJK-ZANJQ |
367 |
iSCSI |
iSER |
365 |
FC |
iSER |
PGR-IWB-Z48PC |
366 |
FC |
SRP |
9GU-2WB-Z503D |
368 |
iSCSI |
SRP |
SGJ-IWB-ZJFE4 |
385 |
Not Available |
NVMe/IB |
UGM-2XB-ZKV0B |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
8GR-QKK-ZFJTP |
368 |
iSCSI |
SRP |
365 |
FC |
iSER |
YG0-LXB-ZLD26 |
366 |
FC |
SRP |
SGR-5XB-ZNTFB |
367 |
iSCSI |
SRP |
PGZ-5WB-Z8M0N |
385 |
Not Available |
NVMe/IB |
KG2-0WB-Z9477 |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
2GV-TKK-ZIHI6 |
384 |
Not Available |
NVMe/IB |
365 |
FC |
iSER |
SGF-SVB-ZWU9M |
366 |
FC |
SRP |
7GH-CVB-ZYBGV |
367 |
iSCSI |
iSER |
6GK-VVB-ZZSRN |
368 |
iSCSI |
SRP |
RGM-FWB-Z195H |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
VGM-NKK-ZDLDK |
385 |
Not Available |
NVMe/IB |
365 |
FC |
iSER |
GG5-8WB-ZBKEM |
366 |
FC |
SRP |
KG7-RWB-ZC2RZ |
367 |
iSCSI |
iSER |
NGC-VWB-ZFZEN |
368 |
iSCSI |
SRP |
4GE-FWB-ZGGQJ |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
NG1-WKK-ZLFAI |
405 |
Not Available |
NVMe/RoCE or NVMe/FC |
365 |
FC |
iSER |
MG6-ZKK-ZNDVC |
366 |
FC |
SRP |
WG9-JKK-ZPUAR |
367 |
iSCSI |
iSER |
NGE-MKK-ZRSW9 |
368 |
iSCSI |
SRP |
TGG-6KK-ZT9BU |
384 |
Not Available |
NVMe/IB |
AGB-3KK-ZQBLR |
385 |
Not Available |
NVMe/IB |
JGJ-PKK-ZUQG2 |
Note: If your controller submodel ID is not listed, contact
NetApp Support.
- In System Manager, locate the Feature Enable Identifier.
- Go to .
- Scroll down to Add-ons.
- Under Change Feature Pack, locate the Feature Enable Identifier.
- Copy and paste this 32-digit number to a text file.
- Go to NetApp License Activation: Storage Array Premium Feature Activation, and enter the information required to obtain the feature pack.
- Chassis serial number
- Feature Activation Code
- Feature Enable Identifier
Important: The Premium Feature Activation web site includes a link to “Premium Feature Activation Instructions.” Do not attempt to use those instructions for this procedure.
- Choose whether to receive the key file for the feature pack in an email or download it directly from the site.
After you finish
Go to Stop host I/O.