You complete the power supply replacement by confirming that the new power supply (referred to in SANtricity System Manager as a power-fan canister) is working correctly. Then, you can gather support data and resume normal operations.
Steps
- On the new power supply, check that the green Power LED is on and the amber Attention LED is OFF.
- From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the problem has been resolved.
- If a failed power supply is still being reported, repeat the steps in Remove power supply and Install new power supply. If the problem continues to persist, contact technical support.
- Remove the antistatic protection.
- Collect support data for your storage array using SANtricity System Manager.
- Select .
- Select Collect Support Data.
- Click Collect.
The file is saved in the Downloads folder for your browser with the
name
support-data.7z.
- Return the failed part to NetApp, as described in the RMA instructions shipped with the kit.
Result
Your power supply replacement is complete. You can resume normal operations.