You must power on the controller shelf to confirm that it is working correctly.
Complete controller replacement type | Procedure and prerequisites |
---|---|
All unsecured drives, neither External or Internal Key Management | Proceed to After you finish. |
Mix of secured and unsecured drives, Internal Key Management | You first must create an internal security key and then import the security key manually to unlock the secured drives. After the drives are unlocked, you can access the drives. |
All secured drives, Internal Key Management | Controller swap with internal key management and one or more drives secured |
Mix of secured and unsecured drives, External Key Management | Proceed to After you finish. Attention: After performing the controller replacement, the controllers will automatically resynchronize with the External Key Management Server and the drives will unlock and be accessible.
Note: If you receive a seven-segment display lock-down code of L5 after performing a controller replacement of mixed secured drives with internal key management, contact technical support.
|
All secured drives, External Key Management, you have temporarily switched back to Internal Key Management for the controller replacement procedure | You must first unlock the secured drives using the Internal Key Management procedure. After the drives are unlocked, then you transition back to External Key Management by creating a new external security key for the storage array. |
All secured drives, External Key Management, you have not temporarily switched to Internal Key Management for the controller replacement procedure | Controller swap with external key management and all drives secured |