You can use the Alert Monitor tab in the web UI on a management node to run a system test and configure settings for a NetApp HCI monitor server.
https://<IP address>:442
The following table details the configuration options for the alert monitor functionality:
Option | Description |
---|---|
Run Alert Monitor Tests |
Runs the monitor system tests to check for the following:
|
Collect Alerts | Enables or disables the forwarding of NetApp HCI storage alarms to vCenter. You can select the target storage cluster from the drop-down list. The default setting for this option is Enabled. |
Collect Best Practice Alerts | Enables or disables the forwarding of NetApp HCI storage Best Practice alerts to vCenter. Best Practice alerts are faults that are triggered by a sub-optimal system configuration. The default setting for this option is Disabled. When disabled, NetApp HCI storage Best Practice alerts do not appear in vCenter. |
Collect ONTAP Alerts | Enables or disables the forwarding of ONTAP Select alarms to vCenter. When disabled, ONTAP Select alarms do not appear in vCenter. |
Send Support Data To AIQ | Controls the flow of support and monitoring data from VMware vCenter to SolidFire Active IQ.
|
Send Compute Node Data To AIQ | Controls the flow of support and monitoring data from the compute nodes to AIQ.
|