Completa la migrazione da switch CN1610 a switch 3232C
Completare i seguenti passaggi per finalizzare la migrazione degli switch CN1610 agli switch Nexus 3232C.
-
Ripristinare tutte le LIF di interconnessione cluster migrate originariamente collegate a C1 su tutti i nodi:
network interface revert -server cluster -lif lif-name
Mostra esempio
È necessario migrare ciascun LIF singolarmente, come illustrato nell'esempio seguente:
cluster::*> network interface revert -vserver cluster -lif n1_clus1 cluster::*> network interface revert -vserver cluster -lif n1_clus4 cluster::*> network interface revert -vserver cluster -lif n2_clus1 cluster::*> network interface revert -vserver cluster -lif n2_clus4
-
Verificare che l'interfaccia sia in posizione iniziale:
network interface show -role cluster
Mostra esempio
L'esempio seguente mostra lo stato delle interfacce di interconnessione del cluster
up
E "is Home" per i nodi n1 e n2:cluster::*> network interface show -role cluster (network interface show) Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home -------- ---------- ----------- -------------- -------- -------- ----- Cluster n1_clus1 up/up 10.10.0.1/24 n1 e0a true n1_clus2 up/up 10.10.0.2/24 n1 e0b true n1_clus3 up/up 10.10.0.3/24 n1 e0c true n1_clus4 up/up 10.10.0.4/24 n1 e0d true n2_clus1 up/up 10.10.0.5/24 n2 e0a true n2_clus2 up/up 10.10.0.6/24 n2 e0b true n2_clus3 up/up 10.10.0.7/24 n2 e0c true n2_clus4 up/up 10.10.0.8/24 n2 e0d true 8 entries were displayed.
-
Verificare la connettività delle interfacce del cluster remoto:
È possibile utilizzare network interface check cluster-connectivity
per avviare un controllo di accessibilità per la connettività del cluster e visualizzare i dettagli:
network interface check cluster-connectivity start
e. network interface check cluster-connectivity show
cluster1::*> network interface check cluster-connectivity start
NOTA: attendere alcuni secondi prima di eseguire il show
comando per visualizzare i dettagli.
cluster1::*> network interface check cluster-connectivity show Source Destination Packet Node Date LIF LIF Loss ------ -------------------------- ---------------- ---------------- ----------- n1 3/5/2022 19:21:18 -06:00 n1_clus2 n2-clus1 none 3/5/2022 19:21:20 -06:00 n1_clus2 n2_clus2 none n2 3/5/2022 19:21:18 -06:00 n2_clus2 n1_clus1 none 3/5/2022 19:21:20 -06:00 n2_clus2 n1_clus2 none
Per tutte le release di ONTAP, è possibile utilizzare anche cluster ping-cluster -node <name>
comando per controllare la connettività:
cluster ping-cluster -node <name>
cluster1::*> cluster ping-cluster -node local Host is n1 Getting addresses from network interface table... Cluster n1_clus1 n1 e0a 10.10.0.1 Cluster n1_clus2 n1 e0b 10.10.0.2 Cluster n1_clus3 n1 e0c 10.10.0.3 Cluster n1_clus4 n1 e0d 10.10.0.4 Cluster n2_clus1 n2 e0a 10.10.0.5 Cluster n2_clus2 n2 e0b 10.10.0.6 Cluster n2_clus3 n2 e0c 10.10.0.7 Cluster n2_clus4 n2 e0d 10.10.0.8 Local = 10.10.0.1 10.10.0.2 10.10.0.3 10.10.0.4 Remote = 10.10.0.5 10.10.0.6 10.10.0.7 10.10.0.8 Cluster Vserver Id = 4294967293 Ping status: .... Basic connectivity succeeds on 16 path(s) Basic connectivity fails on 0 path(s) ................ Detected 9000 byte MTU on 16 path(s): Local 10.10.0.1 to Remote 10.10.0.5 Local 10.10.0.1 to Remote 10.10.0.6 Local 10.10.0.1 to Remote 10.10.0.7 Local 10.10.0.1 to Remote 10.10.0.8 Local 10.10.0.2 to Remote 10.10.0.5 Local 10.10.0.2 to Remote 10.10.0.6 Local 10.10.0.2 to Remote 10.10.0.7 Local 10.10.0.2 to Remote 10.10.0.8 Local 10.10.0.3 to Remote 10.10.0.5 Local 10.10.0.3 to Remote 10.10.0.6 Local 10.10.0.3 to Remote 10.10.0.7 Local 10.10.0.3 to Remote 10.10.0.8 Local 10.10.0.4 to Remote 10.10.0.5 Local 10.10.0.4 to Remote 10.10.0.6 Local 10.10.0.4 to Remote 10.10.0.7 Local 10.10.0.4 to Remote 10.10.0.8 Larger than PMTU communication succeeds on 16 path(s) RPC status: 4 paths up, 0 paths down (tcp check) 3 paths up, 0 paths down (udp check)
-
espandere il cluster aggiungendo nodi agli switch del cluster Nexus 3232C.
-
Visualizzare le informazioni relative ai dispositivi nella configurazione:
-
network device-discovery show
-
network port show -role cluster
-
network interface show -role cluster
-
system cluster-switch show
Mostra esempio
I seguenti esempi mostrano i nodi n3 e n4 con porte cluster da 40 GbE collegate rispettivamente alle porte e1/7 e e1/8 su entrambi gli switch cluster Nexus 3232C. Entrambi i nodi sono Uniti al cluster. Le porte di interconnessione del cluster da 40 GbE utilizzate sono e4a e e4e.
cluster::*> network device-discovery show Local Discovered Node Port Device Interface Platform ------ ------ ------------ --------------- ------------- n1 /cdp e0a C1 Ethernet1/1/1 N3K-C3232C e0b C2 Ethernet1/1/1 N3K-C3232C e0c C2 Ethernet1/1/2 N3K-C3232C e0d C1 Ethernet1/1/2 N3K-C3232C n2 /cdp e0a C1 Ethernet1/1/3 N3K-C3232C e0b C2 Ethernet1/1/3 N3K-C3232C e0c C2 Ethernet1/1/4 N3K-C3232C e0d C1 Ethernet1/1/4 N3K-C3232C n3 /cdp e4a C1 Ethernet1/7 N3K-C3232C e4e C2 Ethernet1/7 N3K-C3232C n4 /cdp e4a C1 Ethernet1/8 N3K-C3232C e4e C2 Ethernet1/8 N3K-C3232C 12 entries were displayed. cluster::*> network port show -role cluster (network port show) Node: n1 Broadcast Speed (Mbps) Health Ignore Port IPspace Domain Link MTU Admin/Open Status Health Status ----- --------- ---------- ----- ----- ------------ -------- ------------- e0a cluster cluster up 9000 auto/10000 - e0b cluster cluster up 9000 auto/10000 - e0c cluster cluster up 9000 auto/10000 - - e0d cluster cluster up 9000 auto/10000 - - Node: n2 Broadcast Speed (Mbps) Health Ignore Port IPspace Domain Link MTU Admin/Open Status Health Status ----- --------- ---------- ----- ----- ------------ -------- ------------- e0a cluster cluster up 9000 auto/10000 - e0b cluster cluster up 9000 auto/10000 - e0c cluster cluster up 9000 auto/10000 - e0d cluster cluster up 9000 auto/10000 - - Node: n3 Broadcast Speed (Mbps) Health Ignore Port IPspace Domain Link MTU Admin/Open Status Health Status ----- --------- ---------- ----- ----- ------------ -------- ------------- e4a cluster cluster up 9000 auto/40000 - e4e cluster cluster up 9000 auto/40000 - - Node: n4 Broadcast Speed (Mbps) Health Ignore Port IPspace Domain Link MTU Admin/Open Status Health Status ----- --------- ---------- ----- ----- ------------ -------- ------------- e4a cluster cluster up 9000 auto/40000 - e4e cluster cluster up 9000 auto/40000 - 12 entries were displayed. cluster::*> network interface show -role cluster (network interface show) Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home -------- ---------- ----------- -------------- -------- -------- ----- Cluster n1_clus1 up/up 10.10.0.1/24 n1 e0a true n1_clus2 up/up 10.10.0.2/24 n1 e0b true n1_clus3 up/up 10.10.0.3/24 n1 e0c true n1_clus4 up/up 10.10.0.4/24 n1 e0d true n2_clus1 up/up 10.10.0.5/24 n2 e0a true n2_clus2 up/up 10.10.0.6/24 n2 e0b true n2_clus3 up/up 10.10.0.7/24 n2 e0c true n2_clus4 up/up 10.10.0.8/24 n2 e0d true n3_clus1 up/up 10.10.0.9/24 n3 e4a true n3_clus2 up/up 10.10.0.10/24 n3 e4e true n4_clus1 up/up 10.10.0.11/24 n4 e4a true n4_clus2 up/up 10.10.0.12/24 n4 e4e true 12 entries were displayed. cluster::> system cluster-switch show Switch Type Address Model --------------------------- ---------------- ------------- --------- C1 cluster-network 10.10.1.103 NX3232C Serial Number: FOX000001 Is Monitored: true Reason: Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I6(1) Version Source: CDP C2 cluster-network 10.10.1.104 NX3232C Serial Number: FOX000002 Is Monitored: true Reason: Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I6(1) Version Source: CDP CL1 cluster-network 10.10.1.101 CN1610 Serial Number: 01234567 Is Monitored: true Reason: Software Version: 1.2.0.7 Version Source: ISDP CL2 cluster-network 10.10.1.102 CN1610 Serial Number: 01234568 Is Monitored: true Reason: Software Version: 1.2.0.7 Version Source: ISDP 4 entries were displayed.
-
-
Rimuovere gli switch CN1610 sostituiti se non vengono rimossi automaticamente:
system cluster-switch delete -device switch-name
Mostra esempio
È necessario eliminare entrambi i dispositivi singolarmente, come illustrato nell'esempio seguente:
cluster::> system cluster-switch delete –device CL1 cluster::> system cluster-switch delete –device CL2
-
Verificare che siano monitorati gli switch del cluster corretti:
system cluster-switch show
Mostra esempio
L'esempio seguente mostra che gli switch del cluster C1 e C2 sono monitorati:
cluster::> system cluster-switch show Switch Type Address Model --------------------------- ------------------ ---------------- --------------- C1 cluster-network 10.10.1.103 NX3232C Serial Number: FOX000001 Is Monitored: true Reason: Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I6(1) Version Source: CDP C2 cluster-network 10.10.1.104 NX3232C Serial Number: FOX000002 Is Monitored: true Reason: Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I6(1) Version Source: CDP 2 entries were displayed.
-
Se è stata eliminata la creazione automatica del caso, riattivarla richiamando un messaggio AutoSupport:
system node autosupport invoke -node * -type all -message MAINT=END