lun transition 7-mode show

Display the 7-Mode LUN Inventory

Availability: This command is available to cluster administrators at the advanced privilege level.

Description

The lun transition 7-mode show command displays information about LUNs copied from a Data ONTAP 7-Mode system. If no parameters are specified, the command displays the following information about all 7-Mode LUNs:
Note: This command is not supported for a Vserver with Infinite Volume.

Parameters

{ [-fields <fieldname>, ...]
If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
| [-instance ]}
If you specify the -instance parameter, the command displays detailed information about all fields.
[-vserver <Vserver Name>] - Vserver Name
Selects the 7-Mode LUNs in the specified Vserver.
[-path <path>] - LUN Path
Selects the 7-Mode LUNs with the specified path.
[-volume <volume name>] - Volume Name
Selects the 7-Mode LUNs that match the specified volume.
[-ostype {vmware|hyper_v|windows_2008|windows_gpt|windows|linux|xen|solaris|solaris_efi|hpux|aix|netware|openvms}] - OS Type
Selects the 7-Mode LUNs that match the specified operating system type.
[-size <size>] - LUN Size
Selects the 7-Mode LUNs that match the specified size.
[-prefix-size <size>] - Prefix Stream Size
Selects the 7-Mode LUNs that match the specified prefix stream size.
[-suffix-size <size>] - Suffix Stream Size
Selects the 7-Mode LUNs that match the specified suffix stream size.
[-serial <text>] - Serial Number
Selects the 7-Mode LUNs that match the specified serial number for clustered Data ONTAP. LUNs where is-transitioned is false do not have a serial number assigned for clustered Data ONTAP.
[-uuid <UUID>] - UUID
Selects the 7-Mode LUNs that match the specified UUID for clustered Data ONTAP. LUNs where is-transitioned is false do not have a UUID assigned for clustered Data ONTAP.
[-serial-7-mode <text>] - 7-mode Serial Number
Selects the 7-Mode LUNs that match the specified serial number from 7-Mode.
[-is-transitioned {true|false}] - Transition Complete
Selects the 7-Mode LUNs that match the specified transition state. LUNs where this value is true have been transitioned and are available to be mapped for client access. LUNs where this value is false have not yet been transitioned and may not be mapped.
[-vserver-uuid <UUID>] - Vserver UUID
Selects the 7-Mode LUNs that match the specified Vserver UUID.
[-node <nodename>] - Node
Selects the 7-Mode LUNs that match the specified node name.

Examples

The following example displays a summary of all 7-Mode LUNs for the volume vol1 in a Vserver named vs1:

cluster1::*> lun transition 7-mode show -vserver vs1 -volume vol1
Vserver   Path                         Type     Size   Transitioned
--------- ---------------------------- -------- ------ ------------
vs1       /vol/vol1/lun1               linux      10MB false
          /vol/vol1/lun2               linux     500MB true
          /vol/vol1/lun3               linux     500MB true
8 entries were displayed.
        

The following example displays detailed information for the 7-Mode LUN /vol/vol1/lun2 in a Vserver named vs1:

cluster1::*> lun transition 7-mode show -vserver vs1 -path /vol/vol1/lun2

        Vserver Name: vs1
            LUN Path: /vol/vol1/lun2
         Volume Name: vol1
             OS Type: linux
            LUN Size: 500MB
  Prefix Stream Size: 0
  Suffix Stream Size: 0
       Serial Number: BCVvv$DLZu8g
                UUID: f53d603b-9663-4567-9680-95c1a9cc6d9e
7-mode Serial Number: C4eqKotPI8Ui
 Transition Complete: true
        Vserver UUID: be4cc135-163f-11e3-931f-123478563412
                Node: cluster-01