system controller fru show

Display Information About the FRUs in the Controller

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The system controller fru show command displays information about all the controller specific Field Replaceable Units (FRUs) in the cluster. These commands are available for 80xx, 25xx and later systems. Earlier models are not supported. By default, the command displays the following information about all the FRUs in the cluster: To display more details, use the -instance parameter.

Parameters

{ [-fields <fieldname>, ...]
Selects the fields that you specify.
| [-instance ]}
Displays detailed information about the controller specific FRUs in the cluster.
[-node {<nodename>|local}] - Node
Selects information about the FRUs in the specified node.
[-subsystem <Subsystem>] - Subsystem
Selects information about the FRUs of the specified subsystem.
[-serial-number <text>] - FRU Serial Number
Selects information about the FRU with the specified serial number.
[-fru-name <text>] - Name of the FRU
Selects information about the FRU with the specified FRU name.
[-type {controller|psu|fan|dimm|bootmedia|ioxm|nvram|nvdimm}] - FRU Type
Selects information about the FRU with the specified FRU type.
[-name <text>] - FRU Name
Selects information about the FRU with the specified unique name.
[-state <text>] - FRU State
Selects information about the FRU with the specified state.
[-status {ok|ok-with-suppressed|degraded|unreachable|unknown}] - Status
Selects information about the FRU with the specified health monitor status.
[-display-name <text>] - Display Name for the Fru
Selects information about the FRU with the specified display name.
[-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example|ethernet-switch}] - Monitor Name
Selects information about the FRU with the specified health monitor type.
[-model <text>] - Model Type
Selects information about the FRU with the specified model.
[-chassis-id <text>] - Chassis ID
Selects information about the FRU with the specified chassis ID.
[-location <text>] - Location of the FRU
Selects information about the FRU with the specified FRU location.
[-additional-info <text>] - Additional Information About the FRU
Selects information about the FRU with the specified additional information.

Examples

The example below displays information about all controller specific FRUs in the cluster.
cluster1::> system controller fru show
			Node               FRU Name                       Subsystem          Status
			------------------ ----------------------------   ------------------ -----------
			node1              PSU1 FRU                       Environment        ok
			node1              PSU2 FRU                       Environment        ok
			node1              DIMM-NV1                       Memory             ok
			node1              DIMM-1                         Memory             ok
			node1              Micron Technology 0x655 (ad.0) Motherboard        ok

			node2              PSU1 FRU                       Environment        ok
			node2              PSU2 FRU                       Environment        ok
			node2              DIMM-NV1                       Memory             ok
			node2              DIMM-1                         Memory             ok
			node2              Micron Technology 0x655 (ad.0) Motherboard        ok
			10 entries were displayed.
		
The example below displays information about the specific FRU.
cluster1::> system controller fru show -instance -serial-number AD-01-1306-2EA01E9A
                                        Node: node1 
                                   Subsystem: Memory
                           FRU Serial Number: AD-01-1306-2EA01E9A
                             Name of the FRU: DIMM-1
                                    FRU Type: dimm
                                    FRU Name: DIMM-1
                                   FRU State: ok
                                      Status: ok
                    Display Name for the Fru: DIMM-1
                                Monitor Name: controller
                                  Model Type: none
                                  Chassis ID: 4591227214
                         Location of the FRU: Memory Slot: 1
         Additional Information About the FRU: Part No: HMT82GV7MMR4A-H9