You must create required zones on the SAN switches for connecting the source storage to the destination storage.
The following is an example of the production zone, production fabric A for zone ZONE_AMS2100_cDOT_Initiator_fabA.
WWPN | Zone Members |
---|---|
50:06:0e:80:10:46:b9:60 |
AMS2100 Ctrl 0 Port 0a |
50:06:0e:80:10:46:b9:68 |
AMS2100 Ctrl 1 Port 1a |
50:0a:09:80:00:d3:51:59 |
ONTAP Node 1 Port 0a |
50:0a:09:80:00:e7:81:04 |
ONTAP Node 2 Port 0a |
The following is an example of the production zone, production fabric A for zone ZONE_AMS2100_cDOT_Initiator_fabB.
WWPN | Zone Members |
---|---|
50:06:0e:80:10:46:b9:64 |
AMS2100 Ctrl 0 Port 0e |
50:06:0e:80:10:46:b9:6c |
AMS2100 Ctrl 1 Port 1e |
50:0a:09:80:00:d3:51:59 |
ONTAP Node 1 Port 0b |
50:0a:09:80:00:e7:81:04 |
ONTAP Node 2 Port 0b |