Skip to main content
ONTAP MetroCluster

Port assignments for systems using two initiator ports

Contributors netapp-pcarriga netapp-thomi netapp-martyh netapp-ranuk

You can configure FAS8020, AFF8020, FAS8200, and AFF A300 systems using a single initiator port for each fabric and two initiator ports for each controller.

You can follow the cabling for the FibreBridge 7500N or 7600N bridge using only one FC port (FC1 or FC2). Instead of using four initiators, connect only two initiators and leave the other two that are connected to the switch port empty.

If zoning is performed manually, then follow the zoning used for a FibreBridge 7500N or 7600N bridge using one FC port (FC1 or FC2). In this scenario, one initiator port rather than two is added to each zone member per fabric.

You can change the zoning or perform an upgrade from a FibreBridge 6500N to a FibreBridge 7500N using the procedure in Hot-swapping a FibreBridge 6500N bridge with a FibreBridge 7600N or 7500N bridge.

The following table shows port assignments for FC switches when using ONTAP 9.1 and later.

Configurations using FibreBridge 7500N or 7600N using one FC port (FC1 or FC2) only

MetroCluster 1 or DR Group 1

Component

Port

Brocade switch models 6505, 6510, 6520, 7840, G620, G610, and DCX 8510-8

Connects to FC switch…​

Connects to switch port…​

controller_x_1

FC-VI port a

1

0

FC-VI port b

2

0

FC-VI port c

1

1

FC-VI port d

2

1

HBA port a

1

2

HBA port b

2

2

HBA port c

-

-

HBA port d

-

-

Stack 1

bridge_x_1a

1

8

bridge_x_1b

2

8

Stack y

bridge_x_ya

1

11

bridge_x_yb

2

11

The following table shows port assignments for FC switches when using ONTAP 9.0.

MetroCluster two-node configuration

Component

Port

Brocade 6505, 6510, or DCX 8510-8

FC_switch_x_1

FC_switch_x_2

controller_x_1

FC-VI port a

0

-

FC-VI port b

-

0

HBA port a

1

-

HBA port b

-

1

HBA port c

2

-

HBA port d

-

2