You must download the switch operating system file and RCF file to each switch in the MetroCluster IP configuration.
This task requires file transfer software, such as FTP, TFTP, SFTP, or SCP, to copy the files to the switches.
You must use the supported switch software version.
IP_switch_A_1# copy sftp://root@10.10.99.99/tftpboot/nxos.7.0.3.I4.6.bin bootflash: vrf management root@10.10.99.99's password: password sftp> progress Progress meter enabled sftp> get /tftpboot/nxos.7.0.3.I4.6.bin /bootflash/nxos.7.0.3.I4.6.bin Fetching /tftpboot/nxos.7.0.3.I4.6.bin to /bootflash/nxos.7.0.3.I4.6.bin /tftpboot/nxos.7.0.3.I4.6.bin 100% 666MB 7.2MB/s 01:32 sftp> exit Copy complete, now saving to disk (please wait)...
IP_switch_A_1# dir bootflash: . . . 698629632 Jun 13 21:37:44 2017 nxos.7.0.3.I4.6.bin . . . Usage for bootflash://sup-local 1779363840 bytes used 13238841344 bytes free 15018205184 bytes total IP_switch_A_1#
IP_switch_A_1# install all nxos bootflash:nxos.7.0.3.I4.6.bin Installer will perform compatibility check first. Please wait. Installer is forced disruptive Verifying image bootflash:/nxos.7.0.3.I4.6.bin for boot variable "nxos". [####################] 100% -- SUCCESS Verifying image type. [####################] 100% -- SUCCESS Preparing "nxos" version info using image bootflash:/nxos.7.0.3.I4.6.bin. [####################] 100% -- SUCCESS Preparing "bios" version info using image bootflash:/nxos.7.0.3.I4.6.bin. [####################] 100% -- SUCCESS [####################] 100% -- SUCCESS Performing module support checks. [####################] 100% -- SUCCESS Notifying services about system upgrade. [####################] 100% -- SUCCESS Compatibility check is done: Module bootable Impact Install-type Reason ------ -------- -------------- ------------ ------ 1 yes disruptive reset default upgrade is not hitless Images will be upgraded according to following table: Module Image Running-Version(pri:alt) New-Version Upg-Required ------ ---------- ------------------------ ------------------ ------------ 1 nxos 7.0(3)I4(1) 7.0(3)I4(6) yes 1 bios v04.24(04/21/2016) v04.24(04/21/2016) no Switch will be reloaded for disruptive upgrade. Do you want to continue with the installation (y/n)? [n] y Install is in progress, please wait. Performing runtime checks. [####################] 100% -- SUCCESS Setting boot variables. [####################] 100% -- SUCCESS Performing configuration copy. [####################] 100% -- SUCCESS Module 1: Refreshing compact flash and upgrading bios/loader/bootrom. Warning: please do not remove or power off the module at this time. [####################] 100% -- SUCCESS Finishing the upgrade, switch will reboot in 10 seconds. IP_switch_A_1#
User Access Verification IP_switch_A_1 login: admin Password: Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2017, Cisco and/or its affiliates. All rights reserved. . . . MDP database restore in progress. IP_switch_A_1# The switch software is now installed.
IP_switch_A_1# show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2017, Cisco and/or its affiliates. All rights reserved. . . . Software BIOS: version 04.24 NXOS: version 7.0(3)I4(6) <<< switch software version BIOS compile time: 04/21/2016 NXOS image file is: bootflash:///nxos.7.0.3.I4.6.bin NXOS compile time: 3/9/2017 22:00:00 [03/10/2017 07:05:18] Hardware cisco Nexus 3132QV Chassis Intel(R) Core(TM) i3- CPU @ 2.50GHz with 16401416 kB of memory. Processor Board ID FOC20123GPS Device name: A1 bootflash: 14900224 kB usb1: 0 kB (expansion flash) Kernel uptime is 0 day(s), 0 hour(s), 1 minute(s), 49 second(s) Last reset at 403451 usecs after Mon Jun 10 21:43:52 2017 Reason: Reset due to upgrade System version: 7.0(3)I4(1) Service: plugin Core Plugin, Ethernet Plugin IP_switch_A_1#