执行切回

修复 MetroCluster 配置后,您可以执行 MetroCluster 切回操作。MetroCluster 切回操作会将配置恢复到其正常运行状态,并将灾难站点上的 sync-source Storage Virtual Machine (SVM) 置于活动状态和通过本地磁盘池提供数据。

开始之前

注:恢复站点可能需要几小时才能执行切回操作。

步骤

  1. 确认所有节点均处于已启用状态:metrocluster node show
    示例
    以下示例显示了处于已启用状态的节点:
    cluster_B::>  metrocluster node show
    
    DR                        Configuration  DR
    Group Cluster Node        State          Mirroring Mode
    ----- ------- ----------- -------------- --------- --------------------
    1     cluster_A
                  node_A_1    configured     enabled   heal roots completed
                  node_A_2    configured     enabled   heal roots completed
          cluster_B
                  node_B_1    configured     enabled   waiting for switchback recovery
                  node_B_2    configured     enabled   waiting for switchback recovery
    4 entries were displayed.
    
  2. 确认所有 SVM 均已完成重新同步:metrocluster vserver show
  3. 确认修复操作已成功执行任何自动 LIF 迁移操作:metrocluster check lif show
  4. 在运行正常的集群中的任何节点上运行 metrocluster switchback 命令,以执行切回。
  5. 查看切回操作的进度:metrocluster show
    示例

    如果输出显示 waiting-for-switchback,则表示切回操作仍在进行:

    cluster_B::> metrocluster show
    Cluster                   Entry Name          State
    ------------------------- ------------------- -----------
     Local: cluster_B         Configuration state configured
                              Mode                switchover
                              AUSO Failure Domain -
    Remote: cluster_A         Configuration state configured
                              Mode                waiting-for-switchback
                              AUSO Failure Domain -

    如果输出显示 normal,则表示切回操作已完成:

    cluster_B::> metrocluster show
    Cluster                   Entry Name          State
    ------------------------- ------------------- -----------
     Local: cluster_B         Configuration state configured
                              Mode                normal
                              AUSO Failure Domain -
    Remote: cluster_A         Configuration state configured
                              Mode                normal
                              AUSO Failure Domain -
    如果切回需要很长时间才能完成,您可以使用 metrocluster config-replication resync-status show 命令来检查正在进行的基线传输的状态。此命令仅可在高级权限级别下使用。
  6. 重新建立任何 SnapMirror 或 SnapVault 配置。

    注:在 Data ONTAP 8.3 中完成 MetroCluster 切回后,您可以重新建立已丢失的 SnapMirror 配置,但在 ONTAP 9.0 及更高版本则不需要。