RCFは、Broadcom対応BES-53248クラスタ スイッチを初めてセットアップしたあとと、新しいライセンスを適用したあとにインストールできます。
(cs2) # ping 172.19.2.1 Pinging 172.19.2.1 with 0 bytes of data: Reply From 172.19.2.1: icmp_seq = 0. time= 5910 usec.
(cs2) # copy sftp://root@172.19.2.1//tmp/BES-53248_RCFv1.0.4.txt Remote Password ******** Mode........................................... SFTP Set Server IP.................................. 172.19.2.1 Path........................................... //tmp/ Filename....................................... BES-53248_RCFv1.0.4.txt Data Type...................................... Config Script Destination Filename........................... BES-53248_RCFv1.0.4.scr File with same name already exists. WARNING:Continuing with this command will overwrite the existing file. Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y Validating configuration script... [the script is now displayed line by line] Configuration script validated. File transfer operation completed successfully.
(cs2) # script list Configuration Script Name Size(Bytes) Date of Modification ----------------------------- -------------- --------------------- BES-53248_RCF_v1.0.4.scr 771 2019 02 28 06:48:29 1 configuration script(s) found. 2047 Kbytes free.
ファイルBES-53248_RCD_v1.0.4.scrには、すべてのライセンスがインストールされた状態の、スイッチのすべての設定情報が含まれています。BES-53248スイッチにライセンスがインストールされていない場合、または一部のライセンスがインストールされていない場合は、エラー メッセージが返されます。このエラー メッセージは無視してかまいません。
interface 0/17-0/24 Unrecognized command : interface 0/17-0/24
次の例は、1本のライセンスがインストールされたBES-53248スイッチで返されるエラー メッセージを示しています。
(cs2) # script apply BES-53248_RCF_v1.0.4.scr Are you sure you want to apply the configuration script? (y/n) y The system has unsaved changes. Would you like to save them now? (y/n) y [ Config file 'startup-config' created successfully . Configuration Saved! [The script is now displayed line by line]... interface 0/25-0/32 Unrecognized command : interface 0/25-0/32 Error! in configuration script file at line number 77. CLI Command :: interface 0/25-0/32. Aborting script. Execution of configuration script 'BES-53248_RCF_v1.0.4.scr' could not be completed. WARNING: The running configuration may not be the desired configuration. You might want to reload the saved configuration.
(cs2) # show port all Admin Physical Physical Link Link LACP Actor Intf Type Mode Mode Status Status Trap Mode Timeout --------- ------ --------- ---------- ---------- ------ ------- ------ -------- 0/1 Enable Auto Down Enable Enable long 0/2 Enable Auto Down Enable Enable long 0/3 Enable Auto Down Enable Enable long 0/4 Enable Auto Down Enable Enable long 0/5 Enable Auto Down Enable Enable long 0/6 Enable Auto Down Enable Enable long 0/7 Enable Auto Down Enable Enable long 0/8 Enable Auto Down Enable Enable long 0/9 Enable Auto Down Enable Enable long 0/10 Enable Auto Down Enable Enable long 0/11 Enable Auto Down Enable Enable long 0/12 Enable Auto Down Enable Enable long 0/13 Enable Auto Down Enable Enable long 0/14 Enable Auto Down Enable Enable long 0/15 Enable Auto Down Enable Enable long 0/16 Enable Auto Down Enable Enable long 0/17 Enable Auto Down Enable Enable long 0/18 Enable Auto Down Enable Enable long 0/19 Enable Auto Down Enable Enable long 0/20 Enable Auto Down Enable Enable long 0/21 Enable Auto Down Enable Enable long 0/22 Enable Auto Down Enable Enable long 0/23 Enable Auto Down Enable Enable long 0/24 Enable Auto Down Enable Enable long 0/53 Enable 100G Full Down Enable Enable long 0/54 Enable 100G Full Down Enable Enable long 0/55 Enable 100G Full Down Enable Enable long 0/56 Enable 100G Full Down Enable Enable long
(cs2) # show running-config
(cs2) # write memory This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n) y Config file 'startup-config' created successfully. Configuration Saved!
(cs2) # reload Are you sure you would like to reset the system? (y/n)y System will now restart!