After investigating the StorageGRID Webscale system and verifying that all recorded lost objects are permanently lost or that it is a false alarm, you can reset the value of the Lost Objects attribute to zero.
Before you begin
You must be signed in to the Grid Management Interface using a supported browser.
To perform this task, you need specific access permissions. For details, see information about controlling system access with administration user accounts and groups.
About this task
The Lost Objects attribute might be seen on either of the following pages:
The Grid > site > Storage Node > LDR > Data Store > Overview > Main page
The Grid > site > Storage Node > DDS > Data Store > Overview > Main page
This example shows the LDR > Data Store page.
Steps
Select Grid.
Select Site > Storage Node > LDR > Data Store > Configuration for the Storage Node that has raised the (LOST) Lost Objects alarm.
Select Reset Lost Objects Count.
Click Apply Changes.
The Lost Objects attribute is reset to 0 and the LOST (Lost Objects) alarm clears. It can take a few moments for the Lost Objects attribute to reset and the alarm to clear after you click Apply Changes.
You can optionally reset other related attribute values that may have been incremented in the process of identifying the lost object.