The SG6060 model of the StorageGRID SG6000 appliance includes an SG6000-CN compute controller in a 1U enclosure and two E2800 storage controllers in a 4U, 60-drive controller shelf. Review the diagrams to learn more about each type of controller.
This figure shows the connectors on the back of the SG6000-CN.
Port | Type | Use | |
---|---|---|---|
1 | Interconnect ports 1-4 | 16-Gb/s Fibre Channel (FC), with integrated optics | Connect the SG6000-CN controller to the E2800 controllers (two connections to each E2800). |
2 | Network ports 1-4 | 10-GbE or 25-GbE, based on cable or SFP transceiver type, switch speed, and configured link speed | Connect to the Grid Network and the Client Network for StorageGRID. |
3 | BMC management port | 1-GbE (RJ-45) | Connect to the SG6000-CN baseboard management controller. |
4 | Diagnostic and support ports |
|
Reserved for technical support use. |
5 | Admin Network port 1 | 1-GbE (RJ-45) | Connect the SG6000-CN to the Admin Network for StorageGRID. |
6 | Admin Network port 2 | 1-GbE (RJ-45) | Options:
|
This figure shows the connectors on the back of each of the E2800 controllers.
Port | Type | Use | |
---|---|---|---|
1 | Interconnect ports 1 and 2 | 16-Gb/s FC optical SFP+ | Connect each of the E2800 controllers to the SG6000-CN controller. There are four connections to the SG6000-CN controller (two from each E2800). |
2 | Management ports 1 and 2 | 1-Gb (RJ-45) Ethernet |
|
3 | Diagnostic and support ports |
|
Reserved for technical support use. |
4 | Drive expansion ports | 12Gb/s SAS | Not used. StorageGRID appliances do not support expansion drive shelves. |