Disabling a Default alarm (legacy system)

You can disable one of the legacy Default alarms for the entire system.

Before you begin

About this task

Disabling an alarm for an attribute that currently has an alarm triggered does not clear the current alarm. The alarm will be disabled the next time the attribute crosses the alarm threshold, or you can clear the triggered alarm.
CAUTION:
Do not disable any of the legacy alarms until you have completely transitioned to the new alert system. Otherwise, you might not detect an underlying problem until it has prevented a critical operation from completing.

Procedure

  1. Select Support. Then, in the Alarms (legacy) section of the menu, select Global Alarms.
  2. Search for the Default alarm to disable.
    1. In the Default Alarms section, select Filter by > Attribute Code or Attribute Name.
    2. Type a search string.
      Specify four characters or use wildcards (for example, A??? or AB*). Asterisks (*) represent multiple characters, and question marks (?) represent a single character.
    3. Click the arrow right arrow icon, or press Enter.
    Note: Selecting Disabled Defaults displays a list of all currently disabled Default alarms.
  3. From the search results table, click the Edit icon edit icon for the alarm you want to disable.

    Global Alarms page
    The Enabled check box for the selected alarm becomes active.
  4. Unselect the Enabled check box.
  5. Click Apply Changes.
    The Default alarm is disabled.