When you apply power to the appliance, the BMC logs a series of boot-up codes for the SG6000-CN controller. You can view these codes in several ways.
Method | Required equipment |
---|---|
VGA console |
|
KVM |
|
Serial port |
|
SOL |
|
Code | Indicates |
---|---|
HI | The master boot script has started. |
HP | The system is checking to see if the network interface card (NIC) firmware needs to be updated. |
RB | The system is rebooting after applying firmware updates. |
FP | The hardware subsystem firmware update checks have been completed. Inter-controller communication services are starting. |
HE |
For an appliance Storage Node only: The system is awaiting connectivity with the storage controllers and synchronizing with the SANtricity operating system. Note: If the boot-up procedure does not progress past this stage, perform these steps:
|
HC | The system is checking for existing StorageGRID installation data. |
HO | The StorageGRID Appliance Installer is running. |
HA | StorageGRID is running. |