      hamsg.dskchkpopulateerr events
hamsg.dskChkPopulateErr
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when a disk inventory check cannot be sent to the local node's high-availability (HA) partner because the disk check request could not be correctly constructed.
 - Corrective Action
 - 
Retry the operation. If the problem persists, use the "storage failover show -fields local-missing-disks, partner-missing-disks" command to rescan the disks and to determine the latest ownership. If the disk inventory mismatch is not resolved, check the cabling for either loose connections or for a bad cable on the partner node.
 - Syslog Message
 - 
A disk inventory check cannot be sent to the local node's HA partner. Failure reason: %s.
 - Parameters
 - 
failure_reason (STRING): The reason that the disk inventory check request could not be properly constructed.