nv.flash.predict.fail
- Severity
-
ALERT
- Description
-
This message occurs when ONTAP® determines that failure is forthcoming or has occurred for the associated flash device on the nonvolatile memory (NVRAM) module.
- Corrective Action
-
Replace the device to prevent future failures.
- Syslog Message
-
%s
- Parameters
-
reason (STRING): Reason for failure.
nv.flash.unable.to.monitor
- Severity
-
ALERT
- Description
-
This message occurs when the ONTAP® module that is responsible for monitoring the health of the NVRAM device cannot extract health information. This failure might indicate the NVRAM device is not operating properly.
- Corrective Action
-
Use the "system environment sensors show" command to verify the device's status. If the failure still exists, contact technical support for assistance.
- Syslog Message
-
Unable to monitor NVRAM device "%s".
- Parameters
-
device (STRING): Name of the device.