Skip to main content
SANtricity commands

Reset storage array SAS PHY baseline

Contributors netapp-driley

The reset storageArray SASPHYBaseline command resets the SAS physical layer (SAS PHY) baseline for all devices, and removes the list of errors from the .csv file.

Supported Arrays

This command applies to any individual storage array, including the E4000, E2700, E5600, E2800, E5700, EF600 and EF300 arrays, as long as all SMcli packages are installed.

Roles

To execute this command on an E4000, E2800, E5700, EF600, or EF300 storage array, you must have the Storage Admin role.

Context

The .csv file is generated when you run the save storageArray SASPHYCounts command.

Note

The previous release of the reset storageArray SASPHYBaseline command cleared error counts for all devices except the drives. The reset storageArray SASPHYBaseline command now resets the SAS PHY baseline for the drives as well as the other devices. All errors are deleted from the .csv file.

Syntax

reset storageArray SASPHYBaseline

Parameters

None.

Minimum firmware level

6.10

7.83 resets the SAS PHY baseline for drives.