Specify AutoSupport HTTP(S) delivery method
The set storageArray autoSupport deliveryMethod
command sets up the delivery method for sending AutoSupport messages to HTTP(S).
Supported Arrays
This command applies to an individual E4000, E2800, E5700, EF600 or EF300 storage array. It does not operate on E2700 or E5600 storage arrays.
Roles
To execute this command on an E4000, E2800, E5700, EF600, or EF300 storage array, you must have the Storage Admin or Support Admin role.
Syntax
set storageArray autoSupport deliveryMethod=email mailRelayServer="mail.example.com" senderEmail="sender@example.com"
Parameters
Parameter | Description | ||
---|---|---|---|
|
Allows the user to specify the delivery method for AutoSupport collection. Valid choices are:
|
||
|
Allows the user to connect directly to the destination technical support systems using the HTTP or HTTPS protocol. |
||
|
Allows the user to specify the location of a Proxy Auto-Configuration (PAC) script file |
||
|
Allows the user to specify the HTTP(S) proxy server details required for establishing connection with the destination technical support system. |
||
|
Allows the user to specify the proxy server's host address. Required if proxyServer is used. |
||
|
Allows the user to specify the proxy server's port number. Required if proxyServer is used. |
||
|
Allows the user to specify the proxy server's username if it is configured. |
||
|
Allows the user to specify the proxy server's password if it is configured. |
Minimum Firmware Level
8.40
Examples
SMcli -n Array1 -c "set storageArray autoSupport deliveryMethod=HTTP direct;" SMcli -n Array1 -c "set storageArray autoSupport deliveryMethod=HTTP proxyConfigScript=\"http://company.com/~username/proxy.pac\";" SMcli -n Array1 -c "set storageArray autoSupport deliveryMethod=HTTPS proxyServer hostAddress=10.117.12.112 portNumber=8080 userName=\"tracyt\" password=\"1234456\";" SMcli completed successfully.
Verification
Send a test message using the start storageArray autoSupport deliveryTest
command to verify that your delivery methods are set up correctly.
Minimum firmware level