Skip to main content
FlexPod

Overview

Contributors

This document provides details for configuring a fully redundant, highly available FlexPod Express system. To reflect this redundancy, the components being configured in each step are referred to as either component A or component B. For example, controller A and controller B identify the two NetApp storage controllers that are provisioned in this document. Switch A and switch B identify a pair of Cisco Nexus switches.

In addition, this document describes steps for provisioning multiple Cisco UCS hosts, which are identified sequentially as server A, server B, and so on.

To indicate that you should include information pertinent to your environment in a step, <<text>> appears as part of the command structure. See the following example for the vlan create command:

Controller01> network port vlan create –node <<var_nodeA>> -vlan-name <<var_vlan-name>>

This document enables you to fully configure the FlexPod Express environment. In this process, various steps require you to insert customer-specific naming conventions, IP addresses, and virtual local area network (VLAN) schemes. The following table describes the VLANs required for deployment, as outlined in this guide. This table can be completed based on the specific site variables and used to implement the document configuration steps.

Note If you use separate in-band and out-of-band management VLANs, you must create a layer- 3 route between them. For this validation, a common management VLAN was used.
VLAN name VLAN purpose VLAN ID

Management VLAN

VLAN for management interfaces

3437

vSwitch0

NFS VLAN

VLAN for NFS traffic

3438

vSwitch0

VMware vMotion VLAN

VLAN designated for the movement of virtual machines (VMs) from one physical host to another

3441

vSwitch0

VM traffic VLAN

VLAN for VM application traffic

3442

vSwitch0

iSCSI-A-VLAN

VLAN for iSCSI traffic on fabric A

3439

iScsiBootvSwitch

iSCSI-B-VLAN

VLAN for iSCSI traffic on fabric B

3440

iScsiBootvSwitch

Native VLAN

VLAN to which untagged frames are assigned

2

The VLAN numbers are needed throughout the configuration of FlexPod Express. The VLANs are referred to as <<var_xxxx_vlan>>, where xxxx is the purpose of the VLAN (such as iSCSI-A).

There are two vSwitches created in this validation.

The following table lists the solution vSwitches.

vSwitch name Active adapters Ports MTU Load balancing

vSwitch0

Vmnic2, vmnic4

default (120)

9000

Route based on IP hash

iScsiBootvSwitch

Vmnic3, vmnic5

default (120)

9000

Route based on the originating virtual port ID.

Note The IP hash method of load balancing requires proper configuration for the underlying physical switch using SRC-DST-IP EtherChannel with a static (mode on) port-channel. In the event of intermittent connectivity due to possible switch misconfiguration, temporarily shut down one of the two associated uplink ports on the Cisco switch to restore communication to the ESXi management vmkernel port while troubleshooting the port-channel settings.

The following table lists the VMware VMs that are created.

VM description Host name

VMware vCenter Server

FlexPod-VCSA

Virtual Storage Console

FlexPod-VSC