Gathering cabling information for transition
Before starting copy-free transition, you must gather information about the adapters, ports, disk shelves, and storage connectivity of your 7-Mode controllers, and then plan how to connect the 7-Mode disk shelves to the target cluster nodes.
You must have printed the copy-free transition cabling worksheet.
-
Use Config Advisor to perform a health check on the 7-Mode storage and cabling and collect cabling data.
You should use the
7-Mode Install Checks
option from the “Data ONTAP 7 and 8 (7-Mode)” execution profile. -
Gather the required information about each 7-Mode controller by using the following command:
sysconfig slot_number
You can use the output of this command to identify which ports are used for disk shelf connectivity.
host1> sysconfig 3 slot 3: SAS Host Adapter 3a 24 Disks: 13440.0GB 1 shelf with IOM3 slot 3: SAS Host Adapter 3b 24 Disks: 13440.0GB 1 shelf with IOM3 slot 3: SAS Host Adapter 3c 24 Disks: 13440.0GB 1 shelf with IOM3 slot 3: SAS Host Adapter 3d 24 Disks: 13440.0GB 1 shelf with IOM3
-
From the cluster, run the following nodeshell command on each node:
system node run -node node_name -command sysconfig -a
You can use the output of this command to obtain information about the available ports and expansion card slots.
-
On the target cluster nodes, plan the ports to be used for connecting the 7-Mode disk shelves:
-
Review the available (open) ports.
-
Review the expansion card slots.
-
Plan the expansion card configuration.
You can plan to move the expansion cards from the 7-Mode systems if they are also supported on the destination platform and ONTAP version. You can also plan for PAM cards, if required.
-
Plan the destination ports to use for the disk shelf cabling.
The selection of the destination ports depends on some of the following factors:
-
Separate or existing disk shelf stack
-
Port availability
-
SAS or FC connections
-
Availability of on-board ports or expansion cards
-
-
-
Go to the data center to physically record the port connections on the 7-Mode controllers and target cluster nodes in the cabling worksheet:
-
Record the used ports on the 7-Mode controllers in the cabling worksheet.
-
Record the used ports on the target cluster nodes in the cabling worksheet.
-
Record the destination ports to be used for connecting the 7-Mode disk shelves, as planned in Step #STEP_D0CFE719A0384F7FA5D9E73C8EA6C2E7.
-
Ensure that you have the right cables for connecting the disk shelves.
You should identify any issues with cabling based on the new disk shelf stack location.
-
Plan for longer cable lengths due to ladder racking or data center requirements.
-
Label each disk shelf stack and cable on the 7-Mode controllers.
The best practice is to label the 7-Mode disk shelf stacks in case you want to roll back the transition and have to reconnect the disk shelves to the 7-Mode controllers.
-
Related information