Determining whether VMFS volumes need to be remounted after transition
After transitioning from Data ONTAP operating in 7-Mode to clustered Data ONTAP, you might have VMFS volumes that need to be remounted to bring VMFS datastores and VMs to their pretransition states.
- 
For copy-based transitions, perform these steps before initiating the Storage Cutover operation in the 7-Mode Transition Tool (7MTT).
 - 
For copy-free transitions, perform these steps before initiating the Export & Halt 7-Mode Systems operation in the 7MTT.
 
- 
Open the Inventory Assessment Workbook generated by the Inventory Collect Tool (ICT).
 - 
Click the SAN Host Filesystems tab.
 - 
Check the Drive / Mount / Datastore Name column for the filesystems and datastores mounted on the host before transition.
 - 
Make a note of the corresponding LUN naa IDs in the SCSI Device ID/Device Name column for the datastore.
 - 
Check whether the naa IDs noted for the datastore are listed in the 7MTT mapping file that was generated after the transition.
- 
If none of the naa IDs are present in the 7MTT mapping file, the datastore and its underlying LUNs were not part of the 7MTT transition and no remediation is required.
 - 
If only part of the naa IDs are present in the 7MTT mapping file, your transition is incomplete and you cannot proceed.
 - 
If all naa IDs are present, you must remount your VMFS volumes.
 
 - 
 