system controller memory dimm show
Display the Memory DIMM Table
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system controller memory dimm show
command displays information about the DIMMs in all the nodes in the cluster. These commands are available for 80xx, 25xx and later systems. Earlier models are not supported. By default, the command displays the following information about all the DIMMs in the cluster:
-
Node
-
DIMM name
-
Uncorrectable ECC error count
-
Correctable ECC error count
-
CECC Alert Method
-
CPU socket
-
Channel
-
Slot number
-
Health monitor status
-
Failure reason
To display more details, use the -instance parameter.
Parameters
- {
[-fields <fieldname>,…]
-
Selects the fields that you specify.
- |
[-instance ]
} -
Displays detailed information about the DIMMs in all the controllers in the cluster.
[-node {<nodename>|local}]
- Node-
Selects information about the DIMMs in the specified node.
[-pds-id <integer>]
- DIMM ID-
Selects information about the DIMMs with the specified DIMM ID.
[-slotname <text>]
- Slot Name-
Selects information about the DIMMs with the specified slot name.
[-socket <integer>]
- CPU Socket-
Selects information about the DIMMs with the specified socket ID.
[-channel <integer>]
- Channel-
Selects information about the DIMMs with the specified channel number.
[-slot-no <integer>]
- Slot Number on a Channel-
Selects information about the DIMMs with the specified slot number.
[-serial <text>]
- Serial Number-
Selects information about the DIMMs with the specified serial number.
[-part-no <text>]
- Part Number-
Selects information about the DIMMs with the specified part number.
[-cecc-count <integer>]
- Correctable ECC Error Count-
Selects information about the DIMMs with the specified correctable ECC error count.
[-uecc-count <integer>]
- Uncorrectable ECC Error Count-
Selects information about the DIMMs with the specified uncorrectable ECC error count.
[-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example|ethernet-switch}]
- Health Monitor Name-
Selects information about the DIMMs with the specified health monitor.
[-status {ok|ok-with-suppressed|degraded|unreachable|unknown}]
- Status-
Selects information about the DIMMs with the specified health monitor status.
[-name <text>]
- Unique Name of DIMM-
Selects information about the DIMMs with the specified unique name.
[-display-name <text>]
- Display Name for the DIMM-
Selects information about the DIMMs with the specified display name.
[-alt-cecc-method <text>]
- CECC Alert Method-
Selects information about the DIMMs with the specified CECC error alert method.
[-alt-cecc-dimm {true|false}]
- Replace DIMM-
Selects information about the DIMMs with the specified replace DIMM value.
[-failure-reason <text>]
- Failure Reason-
Selects information about the DIMMs with the specified failure reason.
Examples
The example below displays information about the DIMMs in all the nodes in the cluster.
cluster1::> system controller memory dimm show DIMM UECC CECC Alert CPU Slot Failure Node Name Count Count Method Socket Channel Number Status Reason -------------- ------- -------- -------- ------ ------ ------- ------ ------- -------- node1 DIMM-1 0 0 bucket 0 0 0 unknown disabled DIMM-NV1 0 0 bucket 0 1 1 ok node2 DIMM-1 1 0 bucket 0 0 0 ok node3 DIMM-NV1 0 0 bucket 0 1 1 ok 4 entries were displayed.
The example below displays detailed information about a specific DIMM in a specific controller.
cluster1::> system controller memory dimm show -instance -node node1 -pds-id 1 Node: node1 DIMM ID: 1 Slot Name: DIMM-1 CPU Socket: 0 Channel: 0 Slot Number on a Channel: 0 Serial Number: AD-01-1306-2EA01E9A Part Number: HMT82GV7MMR4A-H9 Correctable ECC Error Count: 0 Uncorrectable ECC Error Count: 0 Health Monitor Name: controller Status: unknown Unique Name of DIMM: DIMM-1 Display Name for the DIMM: DIMM-1 CECC Alert Method: bucket Replace DIMM: false Failure Reason: disabled