Use Oracle Linux 6.7 with ONTAP
You can use the ONTAP SAN host configuration settings to configure Oracle Linux 6.7 with ONTAP as the target.
Install the Linux Unified Host Utilities
The NetApp Linux Unified Host Utilities software package is available on the NetApp Support Site in a 32-bit and 64-bit .rpm file. If you do not know which file is right for your configuration, use the NetApp Interoperability Matrix Tool to verify which one you need.
NetApp strongly recommends installing the Linux Unified Host Utilities, but it is not mandatory. The utilities do not change any settings on your Linux host. The utilities improve management and assist NetApp customer support in gathering information about your configuration.
If you have a version of Linux Unified Host Utilities currently installed, you should either upgrade it, or remove it and follow these steps to install the latest version.
-
Download the 32-bit or 64-bit Linux Unified Host Utilities software package from the NetApp Support Site Site to your host.
-
Use the following command to install the software package:
rpm -ivh netapp_linux_unified_host_utilities-7-1.x86_64
You can use the configuration settings provided in this document to configure cloud clients connected to Cloud Volumes ONTAP and Amazon FSx for ONTAP. |
SAN Toolkit
The toolkit is installed automatically when you install the NetApp Host Utilities package. This kit provides the sanlun
utility, which helps you manage LUNs and HBAs. The sanlun
command returns information about the LUNs mapped to your host, multipathing, and information necessary to create initiator groups.
In the following example, the sanlun lun show
command returns LUN information.
# sanlun lun show all
Example output:
controller(7mode/E-Series)/ device host lun vserver(cDOT/FlashRay) lun-pathname filename adapter protocol size Product ------------------------------------------------------------------------------------ data_vserver /vol/vol1/lun1 /dev/sdb host16 FCP 120.0g cDOT data_vserver /vol/vol1/lun1 /dev/sdc host15 FCP 120.0g cDOT data_vserver /vol/vol2/lun2 /dev/sdd host16 FCP 120.0g cDOT data_vserver /vol/vol2/lun2 /dev/sde host15 FCP 120.0g cDOT
SAN Booting
If you decide to use SAN booting, it must be supported by your configuration. You can use the NetApp Interoperability Matrix Tool to verify that your OS, HBA, HBA firmware and the HBA boot BIOS, and ONTAP version are supported.
-
Map the SAN boot LUN to the host.
-
Verify that multiple paths are available.
Multiple paths become available after the host OS is up and running on the paths. -
Enable SAN booting in the server BIOS for the ports to which the SAN boot LUN is mapped.
For information on how to enable the HBA BIOS, see your vendor-specific documentation.
-
Reboot the host to verify that the boot was successful.
Multipathing
For Oracle Linux 6.7 the /etc/multipath.conf file must exist, but you do not need to make specific changes to the file. Oracle Linux 6.7 is compiled with all settings required to recognize and correctly manage ONTAP LUNs.
To Enable ALUA Handler, perform the following steps:
-
Create a backup of the initrd-image.
-
Append the following parameter value to the kernel for ALUA and non-ALUA to work:
rdloaddriver=scsi_dh_alua
Examplekernel /vmlinuz-3.8.13-68.1.2.el6uek.x86_64 ro root=/dev/mapper/vg_ibmx3550m421096-lv_root rd_NO_LUKSrd_LVM_LV=vg_ibmx3550m421096/lv_root LANG=en_US.UTF-8 rd_NO_MDSYSFONT=latarcyrheb-sun16 crashkernel=256M KEYBOARDTYPE=pc KEYTABLE=us rd_LVM_LV=vg_ibmx3550m421096/lv_swap rd_NO_DM rhgb quiet rdloaddriver=scsi_dh_alua
-
Use the
mkinitrd
command to recreate the initrd-image.
Oracle 6x and later versions use either:
The command:mkinitrd -f /boot/ initrd-"uname -r".img uname -r
Or
The command:dracut -f
-
Reboot the host.
-
Verify the output of the
cat /proc/cmdline
command to ensure that the setting is complete.
You can use themultipath -ll
command to verify the settings for your ONTAP LUNs.
There should be two groups of paths with different priorities. The paths with higher priorities are Active/Optimized, which means they are serviced by the controller where the aggregate is located. The paths with lower priorities are active but are non-optimized because they are served from a different controller. The non-optimized paths are only used when optimized paths are not available.
The following example displays the correct output for an ONTAP LUN with two Active/Optimized paths and two Active/non-Optimized paths:
# multipath -ll 3600a09803831347657244e527766394e dm-5 NETAPP,LUN C-Mode size=80G features='4 queue_if_no_path pg_init_retries 50 retain_attached_hw_handle' hwhandler='1 alua' wp=rw |-+- policy='round-robin 0' prio=50 status=active | |- 0:0:26:37 sdje 8:384 active ready running | |- 0:0:25:37 sdik 135:64 active ready running |-+- policy='round-robin 0' prio=10 status=enabled |- 0:0:18:37 sdda 70:128 active ready running |- 0:0:19:37 sddu 71:192 active ready running
A single LUN shouldn't require more than four paths. More than eight paths might cause path issues during storage failures. |
Recommended Settings
The Oracle Linux 6.7 OS is compiled to recognize ONTAP LUNs and automatically set all configuration parameters correctly.
The multipath.conf
file must exist for the multipath daemon to start. If this file does not exist, you can create an empty, zero-byte file by using the following command:
touch /etc/multipath.conf
The first time you create the multipath.conf
file, you might need to enable and start the multipath services by using the following commands:
# chkconfig multipathd on # /etc/init.d/multipathd start
There is no requirement to add devices directly to the multipath.conf
file, unless you have devices that you do not want multipath to manage or you have existing settings that override defaults. To exclude the unwanted devices, you add the following syntax to the multipath.conf
file, replacing <DevId> with the WWID string of the device you want to exclude:
blacklist { wwid <DevId> devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss.*" }
In the following example, sda
is the local SCSI disk that you want to add to the blacklist.
-
Run the following command to determine the WWID:
# /lib/udev/scsi_id -gud /dev/sda 360030057024d0730239134810c0cb833
-
Add this WWID to the "blacklist" stanza in
/etc/multipath.conf
:blacklist { wwid 360030057024d0730239134810c0cb833 devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss.*" }
You should always check your /etc/multipath.conf
file for legacy settings, especially in the defaults section, that might be overriding default settings.
The following table demonstrates the critical multipathd
parameters for ONTAP LUNs and the required values. If a host is connected to LUNs from other vendors and any of these parameters are overridden, they must be corrected by later stanzas in the multipath.conf
file that apply specifically to ONTAP LUNs. Without this correction, the ONTAP LUNs might not work as expected. You should only override these defaults in consultation with NetApp, the OS vendor, or both, and only when the impact is fully understood.
Parameter | Setting |
---|---|
detect_prio |
yes |
dev_loss_tmo |
"infinity" |
failback |
immediate |
fast_io_fail_tmo |
5 |
features |
"3 queue_if_no_path pg_init_retries 50" |
flush_on_last_del |
"yes" |
hardware_handler |
"0" |
no_path_retry |
queue |
path_checker |
"tur" |
path_grouping_policy |
"group_by_prio" |
path_selector |
"round-robin 0" |
polling_interval |
5 |
prio |
"ontap" |
product |
LUN.* |
retain_attached_hw_handler |
yes |
rr_weight |
"uniform" |
user_friendly_names |
no |
vendor |
NETAPP |
The following example shows how to correct an overridden default. In this case, the multipath.conf
file defines values for path_checker
and detect_prio
that are not compatible with ONTAP LUNs.
If they cannot be removed because of other SAN arrays still attached to the host, these parameters can be corrected specifically for ONTAP LUNs with a device stanza.
defaults { path_checker readsector0 detect_prio no } devices { device { vendor "NETAPP " product "LUN.*" path_checker tur detect_prio yes } }
To configure Oracle Linux 6.7 Red Hat Enterprise Kernel (RHCK), use the recommended settings for Red Hat Enterprise Linux (RHEL) 6.7. |
Known issues
There are no known issues for the Oracle Linux 6.7 with ONTAP release.
For Oracle Linux (Red Hat compatible kernel) known issues, see the known issues for Red Hat Enterprise Linux (RHEL) 6.7. |