Use Red Hat Enterprise Linux 6.5 with ONTAP
You can use the ONTAP SAN host configuration settings to configure Red Hat Enterprise Linux 6.5 with ONTAP as the target.
Install the Linux Unified Host Utilities
The NetApp Linux Unified Host Utilities software package is available on the NetApp Support Site in a 32-bit and 64-bit .rpm file. If you don't know which file is right for your configuration, use the NetApp Interoperability Matrix Tool to verify which one you need.
NetApp strongly recommends installing the Linux Unified Host Utilities, but it's not mandatory. The utilities don't change any settings on your Linux host. The utilities improve management and assist NetApp customer support in gathering information about your configuration.
If you have Linux Unified Host Utilities currently installed, you should either upgrade it to the latest version, or remove it and follow these steps to install the latest version.
-
Download the 32-bit or 64-bit Linux Unified Host Utilities software package from the NetApp Support Site to your host.
-
Install the software package:
rpm -ivh netapp_linux_unified_host_utilities-7-1.x86_64
You can use the configuration settings provided in this document to configure cloud clients connected to Cloud Volumes ONTAP and Amazon FSx for ONTAP. |
SAN Toolkit
The toolkit is installed automatically when you install the NetApp Host Utilities package. This kit provides the sanlun
utility, which helps you manage LUNs and HBAs. The sanlun
command returns information about the LUNs mapped to your host, multipathing, and information necessary to create initiator groups.
In the following example, the sanlun lun show
command returns LUN information.
# sanlun lun show all
Example output:
controller(7mode/E-Series)/ device host lun vserver(cDOT/FlashRay) lun-pathname filename adapter protocol size Product ------------------------------------------------------------------------------------ data_vserver /vol/vol1/lun1 /dev/sdb host16 FCP 120.0g cDOT data_vserver /vol/vol1/lun1 /dev/sdc host15 FCP 120.0g cDOT data_vserver /vol/vol2/lun2 /dev/sdd host16 FCP 120.0g cDOT data_vserver /vol/vol2/lun2 /dev/sde host15 FCP 120.0g cDOT
SAN Booting
If you decide to use SAN booting, it must be supported by your configuration. You can use the NetApp Interoperability Matrix Tool to verify that your OS, HBA, HBA firmware and the HBA boot BIOS, and ONTAP version are supported.
-
Map the SAN boot LUN to the host.
-
Verify that multiple paths are available.
Multiple paths become available after the host operating system is up and running on the paths. -
Enable SAN booting in the server BIOS for the ports to which the SAN boot LUN is mapped.
For information on how to enable the HBA BIOS, see your vendor-specific documentation.
-
Reboot the host to verify that the boot was successful.
Multipathing
For Red Hat Enterprise Linux (RHEL) 6.5 the /etc/multipath.conf file must exist, but you do not need to make specific changes to the file. RHEL 6.5 is compiled with all settings required to recognize and correctly manage ONTAP LUNs.
To Enable ALUA Handler, perform the following steps:
-
Create a backup of the initrd-image.
-
Append the following parameter value to the kernel for ALUA and non-ALUA to work:
rdloaddriver=scsi_dh_alua
Examplekernel /vmlinuz-2.6.32-358.6.1.el6.x86_64 ro root=/dev/mapper/ vg_ibmx355021082-lv_root rd_NO_LUKS rd_LVM_LV=vg_ibmx355021082/ lv_root LANG=en_US.UTF-8 rd_LVM_LV=vg_ibmx355021082/lv_swap rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto KEYBOARDTYPE=pc KEYTABLE=us rd_NO_DM rhgb quiet rdloaddriver=scsi_dh_alua
-
Use the
mkinitrd
command to recreate the initrd-image.
RHEL 6x and later versions use either:
The command:mkinitrd -f /boot/ initrd-"uname -r".img uname -r
Or
The command:dracut -f
-
Reboot the host.
-
Verify the output of the
cat /proc/cmdline
command to ensure that the setting is complete.
You can use the multipath -ll
command to verify the settings for your ONTAP LUNs.
The following sections provide example multipath outputs for a LUN mapped to ASA and non-ASA personas.
All SAN Array configurations
All SAN Array (ASA) configurations optimize all paths to a given LUN, keeping them active. This improves performance by serving I/O operations through all paths at the same time.
The following example displays the correct output for an ONTAP LUN.
# multipath -ll 3600a0980383034466b2b4a3775474859 dm-3 NETAPP,LUN C-Mode size=20G features='4 queue_if_no_path pg_init_retries 50 retain_attached_hw_handle' hwhandler='1 alua' wp=rw |-+- policy='round-robin 0' prio=50 status=active |- 1:0:8:1 sdb 8:16 active ready running |- 2:0:8:1 sdd 8:48 active ready running |- 1:0:9:1 sdc 8:32 active ready running |- 2:0:9:1 sde 8:64 active ready running
A single LUN shouldn't require more than four paths. Having more than four paths might cause path issues during storage failures. |
Non-ASA configurations
For non-ASA configurations, there should be two groups of paths with different priorities. The paths with higher priorities are Active/Optimized, meaning they are serviced by the controller where the aggregate is located. The paths with lower priorities are active but are non-optimized because they are served from a different controller. The non-optimized paths are only used when optimized paths are not available.
The following example displays the correct output for an ONTAP LUN with two Active/Optimized paths and two Active/Non-Optimized paths.
# multipath -ll 3600a0980383034466b2b4a3775474859 dm-3 NETAPP,LUN C-Mode size=20G features='4 queue_if_no_path pg_init_retries 50 retain_attached_hw_handle' hwhandler='1 alua' wp=rw |-+- policy='round-robin 0' prio=50 status=active | |- 1:0:8:1 sdb 8:16 active ready running | `- 2:0:8:1 sdd 8:48 active ready running `-+- policy='round-robin 0' prio=10 status=enabled |- 1:0:9:1 sdc 8:32 active ready running `- 2:0:9:1 sde 8:64 active ready running
A single LUN shouldn't require more than four paths. Having more than four paths might cause path issues during storage failures. |
Recommended Settings
The RHEL 6.5 OS is compiled to recognize ONTAP LUNs and automatically set all configuration parameters correctly for both ASA and non-ASA configuration.
The multipath.conf
file must exist for the multipath daemon to start. If this file doesn't exist, you can create an empty, zero-byte file by using the touch /etc/multipath.conf
command.
The first time you create the multipath.conf
file, you might need to enable and start the multipath services by using the following commands:
chkconfig multipathd on /etc/init.d/multipathd start
You don't need to add anything directly to the multipath.conf
file unless you have devices that you don't want multipath to manage or you have existing settings that override defaults. To exclude unwanted devices, add the following syntax to the multipath.conf
file, replacing <DevId> with the worldwide identifier (WWID) string of the device you want to exclude:
blacklist { wwid <DevId> devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss.*" }
The following example determines the WWID of a device and adds it to the multipath.conf
file.
-
Determine the WWID:
/lib/udev/scsi_id -gud /dev/sda
3600a098038314c4a433f5774717a3046 /lib/udev/scsi_id -gud /dev/sda
360030057024d0730239134810c0cb833
+ `sda` is the local SCSI disk that you want to add to the blacklist. . Add the `WWID` to the blacklist stanza in `/etc/multipath.conf`: [source,cli] +
blacklist {
wwid 3600a098038314c4a433f5774717a3046
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)"
devnode "^hd[a-z]"
devnode "^cciss."
}
Always check your `/etc/multipath.conf` file, especially in the defaults section, for legacy settings that might be overriding default settings. The following table demonstrates the critical `multipathd` parameters for ONTAP LUNs and the required values. If a host is connected to LUNs from other vendors and any of these parameters are overridden, they must be corrected by later stanzas in the `multipath.conf` file that apply specifically to ONTAP LUNs. Without this correction, the ONTAP LUNs might not work as expected. You should only override these defaults in consultation with NetApp, the OS vendor, or both, and only when the impact is fully understood. //ONTAPDOC-2578 9-Dec-2024 //ONTAPDOC-2561 25-Nov-202 [cols=2*,options="header"] |=== | Parameter | Setting | detect_prio | yes | dev_loss_tmo | "infinity" | failback | immediate | fast_io_fail_tmo | 5 | features | "3 queue_if_no_path pg_init_retries 50" | flush_on_last_del | "yes" | hardware_handler | "0" | no_path_retry | queue | path_checker | "tur" | path_grouping_policy | "group_by_prio" | path_selector | "round-robin 0" | polling_interval | 5 | prio | "ontap" | product | LUN.* | retain_attached_hw_handler | yes | rr_weight | "uniform" | user_friendly_names | no | vendor | NETAPP |=== .Example The following example shows how to correct an overridden default. In this case, the `multipath.conf` file defines values for `path_checker` and `no_path_retry` that are not compatible with ONTAP LUNs. If they cannot be removed because of other SAN arrays still attached to the host, these parameters can be corrected specifically for ONTAP LUNs with a device stanza.
defaults {
path_checker readsector0
no_path_retry fail
}
devices {
device {
vendor "NETAPP "
product "LUN.*"
no_path_retry queue
path_checker tur
}
}
=== Configure KVM settings You can use the recommended settings to configure Kernel-based Virtual Machine (KVM) as well. There are no changes required to configure KVM because the LUN is mapped to the hypervisor. //ONTAPDOC-2561 5-Dec-2024 [[known-problems-and-limitations]] == Known issues The RHEL 6.5 with ONTAP release has the following known issues: [cols=3*,options="header"] |=== | NetApp Bug ID | Title | Description | link:https://mysupport.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=760515[760515^] | Path failures or host hangs were observed in RHEL 6.5 8G Qlogic FC SAN host during storage failover operations | Path failures or host hangs were observed in RHEL 6.5 8G Qlogic FC SAN host during storage failover operations. | link:https://mysupport.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=758271[758271^] | bnx2 firmware fails to load when booting with custom initrd (dracut -f) | Broadcom NetXtreme II Gigabit controller ports will not ping due to bnx2 firmware fails to load during boot with custom initrd. | link:https://mysupport.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=799394[799394^] | RHEL 6U5: Emulex 16G FC (LPe16002B-M6) host crash is seen during I/O with storage failover operations | 16G FC Emulex (LPe16002B-M6) host crash is seen during I/O with storage failover operations. | link:https://mysupport.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=786571[786571^] | QLogic FCoE host hangs/path failures observed in RHEL 6.5 during I/O with storage failover operations | QLogic FCoE (QLE8242) host hangs/path failures are observed in RHEL 6.5 during I/O with storage failover operations. In such scenarios, you might see the following message: "Mailbox cmd timeout occurred, cmd=0x54, mb[0]=0x54. Scheduling ISP abort" messages which leads to host hung/path failures. | link:https://mysupport.netapp.com/NOW/cgi-bin/bol?Type=Detail&Display=801580[801580^] | QLogic 16G FC host hangs or path failures observed in RHEL 6.5 during I/O with storage failover operations | The I/O delays of more than 600 seconds are observed with QLogic 16G FC host (QLE2672) during storage failover operations. In such scenarios, the following message is displayed: "Failed mbx[0]=54, mb[1]=0, mb[2]=76b9, mb[3]=5200, cmd=54" |=== // 2024 SEP 2, ONTAPDOC-2345