Configure RHEL 8.2 for NVMe-oF with ONTAP storage
Red Hat Enterpirse Linux (RHEL) hosts support the NVMe over Fibre Channel (NVMe/FC) and NVMe over TCP (NVMe/TCP) protocols with Asymmetric Namespace Access (ANA). ANA provides multipathing functionality equivalent to asymmetric logical unit access (ALUA) in iSCSI and FCP environments.
Learn how to configure NVMe over Fabrics (NVMe-oF) hosts for RHEL 8.2. For more support and feature information, see NVME-oF Overview.
NVMe-oF with RHEL 8.2 has the following known limitations:
-
SAN booting using the NVMe-oF protocol is not currently supported.
-
In-kernel NVMe multipath is disabled by default on NVMe-oF hosts in RHEL 8.2; you must enable it manually.
Step 1: Optionally, enable SAN booting
You can configure your host to use SAN booting to simplify deployment and improve scalability. Use the Interoperability Matrix Tool to verify that your Linux OS, host bus adapter (HBA), HBA firmware, HBA boot BIOS, and ONTAP version support SAN booting.
-
Enable SAN booting in the server BIOS for the ports to which the SAN boot namespace is mapped.
For information on how to enable the HBA BIOS, see your vendor-specific documentation.
-
Reboot the host and verify that the OS is up and running.
Step 2: Verify the software version and NVMe configuration
Check that your system meets software requirements and verify NVMe package installations and host configuration.
-
Install RHEL 8.2 on the server. After the installation is complete, verify that you are running the required RHEL 8.2 kernel:
uname -r
Example RHEL kernel version:
4.18.0-193.el8.x86_64
-
Install the nvme-cli package:
rpm -qa|grep nvme-cli
The following example shows an nvme-cli package version:
nvme-cli-1.9.5.el8.x86_64
-
Enable in-kernel NVMe multipath:
grubby –args=nvme_core.multipath=Y –update-kernel /boot/vmlinuz-4.18.0-193.el8.x86_64
-
On the RHEL 8.2 host, check the host NQN string at
/etc/nvme/hostnqn
:cat /etc/nvme/hostnqn
The following example shows a hostnqn string:
nqn.2014-08.org.nvmexpress:uuid:9ed5b327-b9fc-4cf5-97b3-1b5d986345d1
-
On the RHEL 8.2 host, check the hostnqn string at
/etc/nvme/hostnqn
:vserver nvme subsystem host show -vserver vs_fcnvme_141
Show example
Vserver Subsystem Host NQN ----------- --------------- ----------- --------------- vs_fcnvme_141 nvme_141_1 nqn.2014-08.org.nvmexpress:uuid:9ed5b327-b9fc-4cf5-97b3-1b5d986345d1
If the host NQN strings do not match, use the vserver modify
command to update the host NQN string on the corresponding ONTAP array subsystem to match the host NQN string from/etc/nvme/hostnqn
on the host. -
Reboot the host.
-
Optionally, update the
enable_foreign
setting.To run both NVMe and SCSI traffic on the same host, NetApp recommends using the in-kernel NVMe multipath for ONTAP namespaces and dm-multipath for ONTAP LUNs. To prevent dm-multipath from claiming ONTAP namespace devices, exclude them by adding the
enable_foreign
setting to the/etc/multipath.conf
file:cat /etc/multipath.conf defaults { enable_foreign NONE }
-
Restart the multipathd daemon by running a
systemctl restart multipathd
.
Step 3: Configure NVMe/FC for Broadcom/Emulex
You can configure NVMe/FC for Broadcom/Emulex.
-
Verify that you are using the supported adapter model:
-
Display the model names:
cat /sys/class/scsi_host/host*/modelname
You should see the following output:
LPe32002-M2 LPe32002-M2
-
Display the model descriptions:
cat /sys/class/scsi_host/host*/modeldesc
You should see output similar to:
Emulex LightPulse LPe32002-M2 2-Port 32Gb Fibre Channel Adapter Emulex LightPulse LPe32002-M2 2-Port 32Gb Fibre Channel Adapter
-
-
Verify that the expected output of
lpfc_enable_fc4_type
is set to3
:cat /sys/module/lpfc/parameters/lpfc_enable_fc4_type
-
Verify that the initiator ports are up and running and can see the target LIFs:
cat /sys/class/fc_host/host*/port_name
You should see output similar to:
0x100000109b1c1204 0x100000109b1c1205
-
Verify that your initiator ports are online:
cat /sys/class/fc_host/host*/port_state
You should see the following output:
Online Online
-
Verify that the NVMe/FC initiator ports are enabled and that the target ports are visible:
cat /sys/class/scsi_host/host*/nvme_info
Show example
NVME Initiator Enabled XRI Dist lpfc0 Total 6144 IO 5894 ELS 250 NVME LPORT lpfc0 WWPN x100000109b1c1204 WWNN x200000109b1c1204 DID x011d00 ONLINE NVME RPORT WWPN x203800a098dfdd91 WWNN x203700a098dfdd91 DID x010c07 TARGET DISCSRVC ONLINE NVME RPORT WWPN x203900a098dfdd91 WWNN x203700a098dfdd91 DID x011507 TARGET DISCSRVC ONLINE NVME Statistics LS: Xmt 0000000f78 Cmpl 0000000f78 Abort 00000000 LS XMIT: Err 00000000 CMPL: xb 00000000 Err 00000000 Total FCP Cmpl 000000002fe29bba Issue 000000002fe29bc4 OutIO 000000000000000a abort 00001bc7 noxri 00000000 nondlp 00000000 qdepth 00000000 wqerr 00000000 err 00000000 FCP CMPL: xb 00001e15 Err 0000d906 NVME Initiator Enabled XRI Dist lpfc1 Total 6144 IO 5894 ELS 250 NVME LPORT lpfc1 WWPN x100000109b1c1205 WWNN x200000109b1c1205 DID x011900 ONLINE NVME RPORT WWPN x203d00a098dfdd91 WWNN x203700a098dfdd91 DID x010007 TARGET DISCSRVC ONLINE NVME RPORT WWPN x203a00a098dfdd91 WWNN x203700a098dfdd91 DID x012a07 TARGET DISCSRVC ONLINE NVME Statistics LS: Xmt 0000000fa8 Cmpl 0000000fa8 Abort 00000000 LS XMIT: Err 00000000 CMPL: xb 00000000 Err 00000000 Total FCP Cmpl 000000002e14f170 Issue 000000002e14f17a OutIO 000000000000000a abort 000016bb noxri 00000000 nondlp 00000000 qdepth 00000000 wqerr 00000000 err 00000000 FCP CMPL: xb 00001f50 Err 0000d9f8
Step 4: Optionally, enable 1MB I/O for NVMe/FC
ONTAP reports a Max Data Transfer Size (MDTS) of 8 in the Identify Controller data. This means the maximum I/O request size can be up to 1MB. To issue I/O requests of size 1MB for a Broadcom NVMe/FC host, you should increase the lpfc
value of the lpfc_sg_seg_cnt
parameter to 256 from the default value of 64.
|
These steps don't apply to Qlogic NVMe/FC hosts. |
-
Set the
lpfc_sg_seg_cnt
parameter to 256:cat /etc/modprobe.d/lpfc.conf
You should see an output similar to the following example:
options lpfc lpfc_sg_seg_cnt=256
-
Run the
dracut -f
command, and reboot the host. -
Verify that the value for
lpfc_sg_seg_cnt
is 256:cat /sys/module/lpfc/parameters/lpfc_sg_seg_cnt
Step 5: Validate NVMe-oF
Verify that the in-kernel NVMe multipath status, ANA status, and ONTAP namespaces are correct for the NVMe-oF configuration.
-
Verify that the in-kernel NVMe multipath is enabled:
cat /sys/module/nvme_core/parameters/multipath
You should see the following output:
Y
-
Verify that the appropriate NVMe-oF settings (such as, model set to NetApp ONTAP Controller and load balancing iopolicy set to round-robin) for the respective ONTAP namespaces correctly reflect on the host:
-
Display the subsystems:
cat /sys/class/nvme-subsystem/nvme-subsys*/model
You should see the following output:
NetApp ONTAP Controller NetApp ONTAP Controller
-
Display the policy:
cat /sys/class/nvme-subsystem/nvme-subsys*/iopolicy
You should see the following output:
round-robin round-robin
-
-
Verify that the namespaces are created and correctly discovered on the host:
nvme list
Show example
Node SN Model --------------------------------------------------------- /dev/nvme4n1 81Ix2BVuekWcAAAAAAAB NetApp ONTAP Controller Namespace Usage Format FW Rev ----------------------------------------------------------- 1 21.47 GB / 21.47 GB 4 KiB + 0 B FFFFFFFF
-
Verify that the controller state of each path is live and has the correct ANA status:
nvme list-subsys /dev/nvme0n1
Show example
Nvme-subsysf0 – NQN=nqn.1992-08.com.netapp:sn.341541339b9511e8a9b500a098c80f09:subsystem.rhel_141_nvme_ss_10_0 \ +- nvme0 fc traddr=nn-0x202c00a098c80f09:pn-0x202d00a098c80f09 host_traddr=nn-0x20000090fae0ec61:pn-0x10000090fae0ec61 live optimized +- nvme1 fc traddr=nn-0x207300a098dfdd91:pn-0x207600a098dfdd91 host_traddr=nn-0x200000109b1c1204:pn-0x100000109b1c1204 live inaccessible +- nvme2 fc traddr=nn-0x207300a098dfdd91:pn-0x207500a098dfdd91 host_traddr=nn-0x200000109b1c1205:pn-0x100000109b1c1205 live optimized +- nvme3 fc traddr=nn-0x207300a098dfdd91:pn-0x207700a098dfdd91 host traddr=nn-0x200000109b1c1205:pn-0x100000109b1c1205 live inaccessible
-
Verify that the NetApp plug-in displays the correct values for each ONTAP namespace device:
Columnnvme netapp ontapdevices -o column
Show example
Device Vserver Namespace Path NSID UUID Size ------- -------- ------------------------- ------ ----- ----- /dev/nvme0n1 vs_nvme_10 /vol/rhel_141_vol_10_0/rhel_141_ns_10_0 1 55baf453-f629-4a18-9364-b6aee3f50dad 53.69GB
JSONnvme netapp ontapdevices -o json
Show example
{ "ONTAPdevices" : [ { Device" : "/dev/nvme0n1", "Vserver" : "vs_nvme_10", "Namespace_Path" : "/vol/rhel_141_vol_10_0/rhel_141_ns_10_0", "NSID" : 1, "UUID" : "55baf453-f629-4a18-9364-b6aee3f50dad", "Size" : "53.69GB", "LBA_Data_Size" : 4096, "Namespace_Size" : 13107200 } ]
Step 6: Review the known issues
There are no known issues.