Install the controllers
When you install controllers that will be added to an existing cluster, you must follow the first three steps of the appropriate Installation and Setup Instructions.
|
About this task
As of ONTAP 9.0, HA mode is enabled by default on new hardware. |
-
Obtain the Installation and Setup Instructions for the FAS model number of the controller module that you plan to add to the cluster.
-
For a new controller module, the document is available in the box.
-
For a repurposed controller module, you can download the document. NetApp Documentation
-
-
Follow the Prepare for installation section with the following exceptions:
-
You can skip any instructions about downloading software or a worksheet.
-
You must provide a serial console connection even if it is not mentioned in the Installation and Setup Instructions.
You require a serial console because you must use the nodeshell CLI to configure node-management LIFs.
If the ONTAP section does not mention the serial console, you can see the 7-mode section.
-
-
Follow the Install hardware section.
-
Follow the Cable storage section.
-
Skip most of the Complete System Setup section with the following exceptions:
-
If instructed to, you must power on all disk shelves and check IDs.
-
You must cable the serial console so that you can access the node.
If the ONTAP section does not mention the serial console, you can see the 7-mode section.
-
-
Skip the Complete configuration section.