Verify LUN reporting nodes after moving a volume
You can add LUN reporting nodes to help maintain optimized LUN paths.
If the volume that you move contains LUNs, and the destination aggregate is on another high-availability (HA) pair, ONTAP automatically adds an HA pair to the Selective LUN Map reporting-nodes list
Two LIFs must be configured: one LIF on the destination node and the other LIF on the HA partner of the destination node.
This procedure is required only if you move a volume from one HA pair to a different HA pair. If you move a volume to a different node of the same HA pair—for example, if you have a two-node cluster or a MetroCluster configuration—you can skip this procedure.
-
Verify that the destination node and its partner node are in the reporting-nodes list of the volume. If the nodes are not in the reporting-nodes list, add the destination node and its partner node to the reporting-nodes list of the volume:
lun mapping add-reporting-nodes
-
Rescan from the host to discover the newly added paths.
-
Add the new paths to your MPIO configuration.
-
Remove the previous LUN owner and its partner node from the reporting-nodes list:
lun mapping remove-reporting-nodes -remote-nodes -vserver vserver_name -path lun_path -igroup igroup_name
-
Rescan the host to verify removal of old paths.
See your host documentation for specific steps to rescan your hosts.