Prepare to install NX-OS software and RCF

Contributors netapp-jolieg

Before you install the NX-OS software and the Reference Configuration File (RCF), follow this procedure.

About the examples

The examples in this procedure use the following switch and node nomenclature:

  • The names of the two Cisco switches are cs1 and cs2.

  • The node names are cluster1-01 and cluster1-02.

  • The cluster LIF names are cluster1-01_clus1 and cluster1-01_clus2 for cluster1-01 and cluster1-02_clus1 and cluster1-02_clus2 for cluster1-02.

  • The cluster1::*> prompt indicates the name of the cluster.

About this task

The procedure requires the use of both ONTAP commands and Cisco Nexus 9000 Series Switches commands; ONTAP commands are used unless otherwise indicated.

Steps
  1. If AutoSupport is enabled on this cluster, suppress automatic case creation by invoking an AutoSupport message: system node autosupport invoke -node * -type all -message MAINT=x h

    where x is the duration of the maintenance window in hours.

    Note The AutoSupport message notifies technical support of this maintenance task so that automatic case creation is suppressed during the maintenance window.
  2. Change the privilege level to advanced, entering y when prompted to continue:

    set -privilege advanced

    The advanced prompt (*>) appears.

  3. Display how many cluster interconnect interfaces are configured in each node for each cluster interconnect switch:

    network device-discovery show -protocol cdp

    Show example
    cluster1::*> network device-discovery show -protocol cdp
    
    Node/       Local  Discovered
    Protocol    Port   Device (LLDP: ChassisID)  Interface         Platform
    ----------- ------ ------------------------- ----------------- --------
    cluster1-02/cdp
                e0a    cs1                       Eth1/2            N9K-C9336C
                e0b    cs2                       Eth1/2            N9K-C9336C
    cluster1-01/cdp
                e0a    cs1                       Eth1/1            N9K-C9336C
                e0b    cs2                       Eth1/1            N9K-C9336C
    
    4 entries were displayed.
  4. Check the administrative or operational status of each cluster interface.

    1. Display the network port attributes:

      `network port show –ipspace Cluster`
      Show example
      cluster1::*> network port show -ipspace Cluster
      
      Node: cluster1-02
                                                        Speed(Mbps) Health
      Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status
      --------- ------------ ---------------- ---- ---- ----------- ------
      e0a       Cluster      Cluster          up   9000  auto/10000 healthy
      e0b       Cluster      Cluster          up   9000  auto/10000 healthy
      
      Node: cluster1-01
                                                        Speed(Mbps) Health
      Port      IPspace      Broadcast Domain Link MTU  Admin/Oper  Status
      --------- ------------ ---------------- ---- ---- ----------- ------
      e0a       Cluster      Cluster          up   9000  auto/10000 healthy
      e0b       Cluster      Cluster          up   9000  auto/10000 healthy
      
      4 entries were displayed.
    2. Display information about the LIFs:

      network interface show -vserver Cluster

      Show example
      cluster1::*> network interface show -vserver Cluster
      
                  Logical            Status     Network            Current       Current Is
      Vserver     Interface          Admin/Oper Address/Mask       Node          Port    Home
      ----------- ------------------ ---------- ------------------ ------------- ------- ----
      Cluster
                  cluster1-01_clus1  up/up      169.254.209.69/16  cluster1-01   e0a     true
                  cluster1-01_clus2  up/up      169.254.49.125/16  cluster1-01   e0b     true
                  cluster1-02_clus1  up/up      169.254.47.194/16  cluster1-02   e0a     true
                  cluster1-02_clus2  up/up      169.254.19.183/16  cluster1-02   e0b     true
      
      4 entries were displayed.
  5. Ping the remote cluster LIFs:

    cluster ping-cluster -node node-name

    Show example
    cluster1::*> cluster ping-cluster -node cluster1-02
    Host is cluster1-02
    Getting addresses from network interface table...
    Cluster cluster1-01_clus1 169.254.209.69 cluster1-01     e0a
    Cluster cluster1-01_clus2 169.254.49.125 cluster1-01     e0b
    Cluster cluster1-02_clus1 169.254.47.194 cluster1-02     e0a
    Cluster cluster1-02_clus2 169.254.19.183 cluster1-02     e0b
    Local = 169.254.47.194 169.254.19.183
    Remote = 169.254.209.69 169.254.49.125
    Cluster Vserver Id = 4294967293
    Ping status:
    
    Basic connectivity succeeds on 4 path(s)
    Basic connectivity fails on 0 path(s)
    
    Detected 9000 byte MTU on 4 path(s):
        Local 169.254.19.183 to Remote 169.254.209.69
        Local 169.254.19.183 to Remote 169.254.49.125
        Local 169.254.47.194 to Remote 169.254.209.69
        Local 169.254.47.194 to Remote 169.254.49.125
    Larger than PMTU communication succeeds on 4 path(s)
    RPC status:
    2 paths up, 0 paths down (tcp check)
    2 paths up, 0 paths down (udp check)
  6. Verify that the auto-revert command is enabled on all cluster LIFs:

    network interface show -vserver Cluster -fields auto-revert

    Show example
    cluster1::*> network interface show -vserver Cluster -fields auto-revert
    
              Logical
    Vserver   Interface           Auto-revert
    --------- ––––––-------------- ------------
    Cluster
              cluster1-01_clus1   true
              cluster1-01_clus2   true
              cluster1-02_clus1   true
              cluster1-02_clus2   true
    4 entries were displayed.
  7. For ONTAP 9.8 and later, enable the Ethernet switch health monitor log collection feature for collecting switch-related log files, using the commands:

    system switch ethernet log setup-password and system switch ethernet log enable-collection

    Show example
    cluster1::*> system switch ethernet log setup-password
    Enter the switch name: <return>
    The switch name entered is not recognized.
    Choose from the following list:
    cs1
    cs2
    
    cluster1::*> system switch ethernet log setup-password
    
    Enter the switch name: cs1
    RSA key fingerprint is e5:8b:c6:dc:e2:18:18:09:36:63:d9:63:dd:03:d9:cc
    Do you want to continue? {y|n}::[n] y
    
    Enter the password: <enter switch password>
    Enter the password again: <enter switch password>
    
    cluster1::*> system switch ethernet log setup-password
    
    Enter the switch name: cs2
    RSA key fingerprint is 57:49:86:a1:b9:80:6a:61:9a:86:8e:3c:e3:b7:1f:b1
    Do you want to continue? {y|n}:: [n] y
    
    Enter the password: <enter switch password>
    Enter the password again: <enter switch password>
    
    cluster1::*> system  switch ethernet log enable-collection
    
    Do you want to enable cluster log collection for all nodes in the cluster?
    {y|n}: [n] y
    
    Enabling cluster switch log collection.
    
    cluster1::*>
    Note If any of these commands return an error, contact NetApp support.
  8. For ONTAP releases 9.5P16, 9.6P12, and 9.7P10 and later patch releases, enable the Ethernet switch health monitor log collection feature for collecting switch-related log files, using the commands:

    system cluster-switch log setup-password and system cluster-switch log enable-collection

    Show example
    cluster1::*> system cluster-switch log setup-password
    Enter the switch name: <return>
    The switch name entered is not recognized.
    Choose from the following list:
    cs1
    cs2
    
    cluster1::*> system cluster-switch log setup-password
    
    Enter the switch name: cs1
    RSA key fingerprint is e5:8b:c6:dc:e2:18:18:09:36:63:d9:63:dd:03:d9:cc
    Do you want to continue? {y|n}::[n] y
    
    Enter the password: <enter switch password>
    Enter the password again: <enter switch password>
    
    cluster1::*> system cluster-switch log setup-password
    
    Enter the switch name: cs2
    RSA key fingerprint is 57:49:86:a1:b9:80:6a:61:9a:86:8e:3c:e3:b7:1f:b1
    Do you want to continue? {y|n}:: [n] y
    
    Enter the password: <enter switch password>
    Enter the password again: <enter switch password>
    
    cluster1::*> system cluster-switch log enable-collection
    
    Do you want to enable cluster log collection for all nodes in the cluster?
    {y|n}: [n] y
    
    Enabling cluster switch log collection.
    
    cluster1::*>
Note If any of these commands return an error, contact NetApp support.