Install the NX-OS - Cisco Nexus 9364D-GX2A
You install the NX-OS on your Cisco Nexus 9364D-GX2A switch(es) as part of a new AFX 1K or AFX 2K system installation, a switch replacement, or a switch reset to factory default settings.
-
The switch(es) must be powered on and you must have completed the Complete initial switch setup procedure.
-
If you are installing the NX-OS on switch(es) as part of a new AFX system installation or switch replacement, verify that the version of NX-OS on your switch(es) is the current NetApp-supported version.
-
If your switch(es) have the current NetApp-supported version, you do not need to install the NX-OS. You need to install the RCF. Start with the Install or upgrade the RCF overview.
-
If your switch(es) do not have the current NetApp-supported version, continue with this procedure to install the NX-OS.
-
-
If you are installing the NX-OS on a switch as part of a switch replacement or a switch reset to factory default settings, verify that your cluster is fully functional, meaning that there are no errors in the logs or similar issues.
|
|
If you are installing the NX-OS as part of a new AFX system installation, you can skip this requirement because the controllers in your AFX system are not powered on at this point in your AFX system installation and setup. |
-
The version of ONTAP running on your AFX system determines the supported versions of NX-OS for your switches.
-
For switches in an AFX 1K system, running any supported version of ONTAP, NX-OS 10.4.2 and later is supported.
-
For switches in an AFX 2K system, running ONTAP 9.19.1GA or later, NX-OS 10.6 and later is supported.
For the current list of supported NX-OS versions, see the NetApp Cisco Ethernet Switches page.
-
-
This procedure only requires the use of Cisco Nexus 9000 Series Switches commands.
-
The examples in this procedure refer to the first switch as cs1 and the second switch as cs2.
-
If you have installed switches as part of a new AFX 1K or AFX 2K system installation, this procedure has you install the NX-OS on the first switch (cs1) and then has you repeat the steps for the second switch (cs2).
-
The examples shown in this procedure are for AFX 1K systems with switches running RCF 10.0. If you have an AFX 2K system, the input and output can vary.
Step 1: Prepare to install the NX-OS
Prepare to install the NX-OS on the switch(es) by making sure you have access to a server with the supported NX-OS version, downloading the NX-OS, connecting to the management network for the file transfer, and then verifying connectivity to the server.
-
You must have access to an HTTP, FTP, or TFTP server. Access to one of these servers allows you to download a supported version of the NX-OS.
-
Download the correct version of NX-OS to the switch(es) from the Cisco software download page.
-
Connect the switch to the management network (for the file transfer).
-
Verify connectivity to the server hosting the NX-OS using the ping command.
ping <IP address>Show example
This example verifies that the switch can reach the server at IP address 172.19.2.1:
cs1# ping 172.19.2.1 Pinging 172.19.2.1 with 0 bytes of data: Reply From 172.19.2.1: icmp_seq = 0. time= 5910 usec.
Step 2: Install the NX-OS
You install the NX-OS on the first switch (cs1) by installing and verifying the NX-OS version, upgrading and verifying the EPLD image, and then repeat these steps on the second switch (cs2) if you are installing the NX-OS as part of a new AFX system installation.
-
Copy NX-OS and EPLD images to the first switch.
You use this command two times: the first time is to copy the NX-OS version and the second time is to copy the EPLD version.
copy <protocol>: bootflash: vrf managementShow example
The example uses sftp.
cs2# copy sftp: bootflash: vrf management Enter source filename: /code/nxos.10.4.2.bin Enter hostname for the sftp server: 172.19.2.1 Enter username: root Outbound-ReKey for 172.19.2.1:22 Inbound-ReKey for 172.19.2.1:22 root@172.19.2.1's password: sftp> progress Progress meter enabled sftp> get /code/nxos.10.4.2.bin /bootflash/nxos.10.4.2.bin /code/nxos.10.4.2.bin 100% 1261MB 9.3MB/s 02:15 sftp> exit Copy complete, now saving to disk (please wait)... Copy complete. cs2# copy sftp: bootflash: vrf management Enter source filename: /code/n9000-epld.10.4.2.F.img Enter hostname for the sftp server: 172.19.2.1 Enter username: user1 Outbound-ReKey for 172.19.2.1:22 Inbound-ReKey for 172.19.2.1:22 user1@172.19.2.1's password: sftp> progress Progress meter enabled sftp> get /code/n9000-epld.10.4.2.F.img /bootflash/n9000-epld.10.4.2.F.img /code/n9000-epld.10.4.2.F.img 100% 161MB 9.5MB/s 00:16 sftp> exit Copy complete, now saving to disk (please wait)... Copy complete.
-
Verify the running version of NX-OS:
show versionShow example
cs2# show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2025, Cisco and/or its affiliates. All rights reserved. The copyrights to certain works contained in this software are owned by other third parties and used and distributed under their own licenses, such as open source. This software is provided "as is," and unless otherwise stated, there is no warranty, express or implied, including but not limited to warranties of merchantability and fitness for a particular purpose. Certain components of this software are licensed under the GNU General Public License (GPL) version 2.0 or GNU General Public License (GPL) version 3.0 or the GNU Lesser General Public License (LGPL) Version 2.1 or Lesser General Public License (LGPL) Version 2.0. A copy of each such license is available at http://www.opensource.org/licenses/gpl-2.0.php and http://opensource.org/licenses/gpl-3.0.html and http://www.opensource.org/licenses/lgpl-2.1.php and http://www.gnu.org/licenses/old-licenses/library.txt. Software BIOS: version 01.14 NXOS: version 10.4(1) [Feature Release] Host NXOS: version 10.4(1) BIOS compile time: 11/25/2024 NXOS image file is: bootflash:///nxos64-cs.10.4.1.F.bin NXOS compile time: 11/30/2023 12:00:00 [12/14/2023 05:25:50] NXOS boot mode: LXC Hardware cisco Nexus9000 C9332D-GX2B Chassis Intel(R) Xeon(R) CPU D-1633N @ 2.50GHz with 32802156 kB of memory. Processor Board ID FLMXXXXXXXX Device name: cs2 bootflash: 115802886 kB Kernel uptime is 5 day(s), 2 hour(s), 13 minute(s), 21 second(s) Last reset at 3580 usecs after Thu Jun 5 15:55:08 2025 Reason: Reset Requested by CLI command reload System version: 10.4(1) Service: plugin Core Plugin, Ethernet Plugin Active Package(s): cs2#
-
Install the NX-OS image.
Installing the image file causes it to be loaded every time the switch is rebooted.
install all nxos bootflash:nxos.<version number>.binShow example
The example uses NX-OS version 10.4.2.
cs2# install all nxos bootflash:nxos.10.4.2.bin Installer will perform compatibility check first. Please wait. Installer is forced disruptive Verifying image bootflash:/nxos.10.4.2.bin for boot variable "nxos". [] 100% -- SUCCESS Verifying image type. [] 100% -- SUCCESS Preparing "nxos" version info using image bootflash:/nxos.10.4.2.bin. [] 100% -- SUCCESS Preparing "bios" version info using image bootflash:/nxos.10.4.2.bin. [] 100% -- SUCCESS Performing module support checks. [] 100% -- SUCCESS Notifying services about system upgrade. [] 100% -- SUCCESS Compatibility check is done: Module Bootable Impact Install-type Reason ------ -------- --------------- ------------ --------- 1 yes Disruptive Reset Default upgrade is not hitless Images will be upgraded according to following table: Module Image Running-Version(pri:alt) New-Version Upg-Required ------- --------- ---------------------------------------- ------------------- ------------ 1 nxos 10.4(1) 10.4(2) Yes 1 bios xx.xx.:xx.xx xxx No Switch will be reloaded for disruptive upgrade. Do you want to continue with the installation (y/n)? [n] y Install is in progress, please wait. Performing runtime checks. [] 100% -- SUCCESS Setting boot variables. [] 100% -- SUCCESS Performing configuration copy. [] 100% -- SUCCESS Module 1: Refreshing compact flash and upgrading bios/loader/bootrom. Warning: please do not remove or power off the module at this time. [] 100% -- SUCCESS Finishing the upgrade, switch will reboot in 10 seconds.
-
Verify the new version of NX-OS after the switch has rebooted:
show versionShow example
cs2# show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (C) 2002-2025, Cisco and/or its affiliates. All rights reserved. The copyrights to certain works contained in this software are owned by other third parties and used and distributed under their own licenses, such as open source. This software is provided "as is," and unless otherwise stated, there is no warranty, express or implied, including but not limited to warranties of merchantability and fitness for a particular purpose. Certain components of this software are licensed under the GNU General Public License (GPL) version 2.0 or GNU General Public License (GPL) version 3.0 or the GNU Lesser General Public License (LGPL) Version 2.1 or Lesser General Public License (LGPL) Version 2.0. A copy of each such license is available at http://www.opensource.org/licenses/gpl-2.0.php and http://opensource.org/licenses/gpl-3.0.html and http://www.opensource.org/licenses/lgpl-2.1.php and http://www.gnu.org/licenses/old-licenses/library.txt. Software BIOS: version 01.14 NXOS: version 10.4(2) [Feature Release] Host NXOS: version 10.4(2) BIOS compile time: 11/25/2024 NXOS image file is: bootflash:///nxos64-cs.10.4.2.F.bin NXOS compile time: 11/30/2023 12:00:00 [12/14/2023 05:25:50] NXOS boot mode: LXC Hardware cisco Nexus9000 C9332D-GX2B Chassis Intel(R) Xeon(R) CPU D-1633N @ 2.50GHz with 32802156 kB of memory. Processor Board ID FLMXXXXXXXX Device name: cs2 bootflash: 115802886 kB Kernel uptime is 5 day(s), 2 hour(s), 13 minute(s), 21 second(s) Last reset at 3580 usecs after Thu Jun 5 15:55:08 2025 Reason: Reset Requested by CLI command reload System version: 10.4(2) Service: plugin Core Plugin, Ethernet Plugin Active Package(s): cs2#
-
Upgrade the EPLD image using the following commands:
show version module 1 epldinstall epld bootflash:n9000-epld.<version>.img module allAfter the last command is executed, the switch reboots.
Show example
The example uses EPLD version 10.4.2.F
cs2# show version module 1 epld EPLD Device Version --------------------------------------- MI FPGA 0x7 IO FPGA 0x17 MI FPGA2 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2 cs2# install epld bootflash:n9000-epld.10.4.2.F.img module all Compatibility check: Module Type Upgradable Impact Reason ------ ------------------ ----------------- --------- ----------- 1 SUP Yes disruptive Module Upgradable Retrieving EPLD versions.... Please wait. Images will be upgraded according to following table: Module Type EPLD Running-Version New-Version Upg-Required ------- ------ ----------------- ----------------- ------------ ------------ 1 SUP MI FPGA 0x07 0x07 No 1 SUP IO FPGA 0x17 0x19 Yes 1 SUP MI FPGA2 0x02 0x02 No The above modules require upgrade. The switch will be reloaded at the end of the upgrade Do you want to continue (y/n) ? [n] y Proceeding to upgrade Modules. Starting Module 1 EPLD Upgrade Module 1 : IO FPGA [Programming] : 100.00% ( 64 of 64 sectors) Module 1 EPLD upgrade is successful. Module Type Upgrade-Result -------- ----- -------------- 1 SUP Success EPLDs upgraded. Module 1 EPLD upgrade is successful. -
After the switch reboot, log in and verify that the new version of EPLD loaded successfully:
show version module 1 epldShow example
cs1# show version module 1 epld EPLD Device Version --------------------------------------- MI FPGA 0x7 IO FPGA 0x19 MI FPGA2 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2 GEM FPGA 0x2
-
If you are installing the NX-OS as part of a new AFX system installation, repeat these steps to install the NX-OS and EPLD images on switch cs2.
After you've installed the NX-OS on your switch(es), you install RCF starting with the Install or upgrade the RCF overview.