Verify the RCF configuration on cluster switches
At this stage in the upgrade procedure, all data aggregates should be on node1. If you're upgrading a configuration with switch-attached clusters, you need to validate that the cluster switch reference configuration file (RCF) supports the shared cluster/HA ports for the new controllers.
If you're upgrading to a two-node switchless cluster configuration, you can skip this section and go to Move non-root aggregates and NAS data LIFs back to node2.
-
Switch to advanced privilege mode:
set advanced
-
Check the status of "IC RDMA":
ha interconnect status show
In the output, the "IC RDMA Connection" should have the status
Up
.If the "IC RDMA Connection" status is … Then… Up
Go to Move non-root aggregates and NAS data LIFs back to node2.
Down
Go to Step 3.
-
Check the cluster ports and switch RCF.
For more information, see Connect to a switch-attached cluster.
-
Verify that the "IC RDMA Connection" status has changed to
Up
:ha interconnect status show