Complete controller replacement - AFF A70 and AFF A90
To complete the controller replacement for your AFF A70 or AFF A90 system, first restore the NetApp Storage Encryption configuration (if necessary). Next, confirm that the logical interfaces (LIFs) are reporting to their home ports and perform a cluster health check. Finally, return the failed part to NetApp.
Step 1: Verify LIFs and check cluster health
Before returning the replacement node to service, verify that the logical interfaces are on their home ports, check the cluster health, and reset automatic giveback.
-
Verify that the logical interfaces are reporting to their home server and ports:
network interface show -is-home false
If any logical interfaces are listed as false, revert them to their home ports:
network interface revert -vserver * -lif *
-
Check the health of your cluster. See the How to perform a cluster health check with a script in ONTAP KB article for more information.
-
If automatic giveback was disabled, reenable it:
storage failover modify -node local -auto-giveback true
Step 2: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return and Replacements page for further information.