Review requirements before replacing the controller in your ASA A20, ASA A30, or ASA A50 system
Before replacing the controller in your ASA A20, ASA A30, or ASA A50 storage system, ensure you meet the necessary requirements for a successful replacement. This includes verifying all other components in the system are functioning properly, verifying that you have the correct replacement controller, and saving the controller's console output to a text log file.
You must review the requirements and considerations for the controller replacement procedure.
|
|
NetApp strongly recommends that you enable console logging on the devices you are working with and take the following actions when performing this procedure:
|
Requirements
-
All shelves must be working properly.
-
The healthy controller must be able to take over the controller that is being replaced (referred to in this procedure as the “impaired controller”).
-
You must replace a controller with a controller of the same model type. You cannot upgrade your system by just replacing the controller.
-
You cannot change any drives or shelves as part of this procedure.
Considerations
-
It is important that you apply the commands in this procedure to the correct controller:
-
The impaired controller is the controller that is being replaced.
-
The replacement controller is the new controller that is replacing the impaired controller.
-
The healthy controller is the surviving controller.
-
After you’ve reviewed the requirements to replace the impaired controller, you need to shut down the impaired controller.