Contributors netapp-lisa netapp-jsnyder

Before replacing the controller in your ASA C30 storage system, ensure you meet the necessary requirements for a successful replacement. This includes verifying all other components in the system are functioning properly, verifying that you have the correct replacement controller, and saving the controller's console output to a text log file.

You must review the requirements and considerations for the controller replacement procedure.

Requirements

  • All shelves must be working properly.

  • The healthy controller must be able to take over the controller that is being replaced (referred to in this procedure as the “impaired controller”).

  • You must replace a controller with a controller of the same model type. You cannot upgrade your system by just replacing the controller.

  • You cannot change any drives or shelves as part of this procedure.

  • You must always capture the controller's console output to a text log file.

    The console output provides you with a record of the procedure you can use to troubleshoot issues you might encounter during the replacement process.

Considerations

  • It is important that you apply the commands in this procedure to the correct controller:

    • The impaired controller is the controller that is being replaced.

    • The replacement controller is the new controller that is replacing the impaired controller.

    • The healthy controller is the surviving controller.

What's next?

After you’ve reviewed the requirements to replace the impaired controller, you need to shut down the impaired controller.