The following are select specifications for the ASA A70 storage system in a single high availability pair. Visit NetApp Hardware Universe (HWU) for the complete specifications for this storage system.
Key capacity, memory, form factor, and ONTAP Version specifications
-
Platform Configuration: ASA A70 Single Chassis HA Pair
-
Max Raw Capacity: 2.6622 PB
-
Memory: 256.0000 GB
-
Form Factor: 4U chassis with 2 HA controllers and 48 drive slots
-
ONTAP Version: ONTAP: 9.16.1P2
-
PCIe Expansion Slots: 18
-
Minimum ONTAP Version: ONTAP 9.16.0 == Scaleout maximums
-
Type: NAS
-
Type: SAN; HA Pairs: 6; Raw Capacity: 16.0 PB / 14.2 PiB; Max Memory: 1536 GB
-
Type: HA Pair; Raw Capacity: 2.7 PB / 2.4 PiB; Max Memory: 256.0000
I/O
Onboard I/O
No onboard I/O data.
Total I/O
-
Protocol: Ethernet 200 Gbps; Ports: 24
-
Protocol: Ethernet 100 Gbps; Ports: 36
-
Protocol: Ethernet 25 Gbps; Ports: 56
-
Protocol: Ethernet 10 Gbps; Ports: 56
-
Protocol: FC 64 Gbps; Ports: 56
-
Protocol: NVMe/FC 64 Gbps; Ports: 56
-
Ports: 0
Management ports
-
Protocol: Ethernet 1 Gbps; Ports: 2
-
Protocol: RS-232 115 Kbps; Ports: 4
-
Protocol: USB 600 Mbps; Ports: 2
Storage networking supported
-
FC
-
iSCSI
-
NVMe/FC
-
NVMe/TCP == System environment specifications
-
Typical Power: 6938 BTU/hr
-
Worst-case Power: 9089 BTU/hr
-
Weight: 170.4 lb 77.3 kg
-
Height: 4U
-
Width: 19” IEC rack-compliant (17.6” 44.7 cm)
-
Depth: 34.5” (36.6” with cable management bracket)
-
Operating Temp/Altitude/Humidity: 10°C to 35°C 50°F to 95°F) at ⇐ 3048m ⇐ 10000 ft) elevation;8% to 80% relative humidity, noncondensing
-
Non-operating Temp/Humidity: -40°C to 70°C (-40°F to 158°F) upto 12192m (40000 ft) 10% to 95% relative humidity, noncondensing, in original container
-
Acoustic Noise: Declared sound power (LwAd): 8.6 Sound pressure (LpAm) (bystander positions): 71.6 dB
Compliance
-
Certifications EMC/EMI: AMCA, FCC, ICES, KC, Morocco, VCCI
-
Certifications safety: BIS, CB, CSA, G_K_U-SoR, IRAM, NOM, NRCS, SONCAP, TBS
-
Certifications Safety/EMC/EMI: EAC, UKRSEPRO
-
Certifications Safety/EMC/EMI/RoHS: BSMI, CE DoC, UKCA DoC
-
Standards EMC/EMI: BS-EN-55032, BS-EN55035, CISPR 32, EN55022, EN55024, EN55032, EN55035, EN61000-3-2, EN61000-3-3, FCC Part 15 Class A, ICES-003, KS C 9832, KS C 9835
-
Standards Safety: ANSI/UL60950-1, ANSI/UL62368-1, BS-EN62368-1, CAN/CSA C22.2 No. 60950-1, CAN/CSA C22.2 No. 62368-1, CNS 15598-1, EN60825-1, EN62368-1, IEC 62368-1, IEC60950-1, IS 13252(part 1)
High availability
-
Ethernet based baseboard management controller (BMC) and ONTAP management interface
-
Redundant hot-swappable controllers
-
Redundant hot-swappable power supplies
-