Contributors netapp-jsnyder

To replace the boot media, you must remove the impaired controller, remove the boot media, install the replacement boot media, and transfer the boot image to a USB flash drive.

Step 1: Remove the controller

You must remove the controller from the chassis when you replace the controller or replace a component inside the controller.

Before you begin

All other components in the storage system must be functioning properly; if not, you must contact NetApp Support before continuing with this procedure.

Steps
  1. On the impaired controller, make sure the NV LED is off.

    When the NV LED is off, destaging is complete and it is safe to remove the impaired controller.

    Note If the NV LED is flashing (green), destage is in progress. You must wait for the NV LED to turn off. However, if the flashing continues for longer than five minutes, contact NetApp Support before continuing with this procedure.

    The NV LED is located next to the NV icon on the controller.

    NV status LED location
Callout number 1

NV icon and LED on the controller

  1. If you are not already grounded, properly ground yourself.

  2. Disconnect the power on the impaired controller:

    Note Power supplies (PSUs) do not have a power switch.
    If you are disconnecting a…​ Then…​

    AC PSU

    1. Open the power cord retainer.

    2. Unplug the power cord from the PSU and set it aside.

    DC PSU

    1. Unscrew the two thumb screws on the D-SUB DC power cord connector.

    2. Unplug the power cord from the PSU and set it aside.

  3. Unplug all cables from the impaired controller.

    Keep track of where the cables were connected.

  4. Remove the impaired controller:

    The following illustration shows the operation of the controller handles (from the left side of the controller) when removing a controller:

    controller handle operation to remove a controller
    Callout number 1

    On both ends of the controller, push the vertical locking tabs outward to release the handles.

    Callout number 2
    • Pull the handles towards you to unseat the controller from the midplane.

      As you pull, the handles extend out from the controller and then you feel some resistance, keep pulling.

    • Slide the controller out of the chassis while supporting the bottom of the controller, and place it on a flat, stable surface.

    Callout number 3

    If needed, rotate the handles upright (next to the tabs) to move them out of the way.

  5. Place the controller on an anti-static mat.

  6. Open the controller cover by turning the thumbscrew counterclockwise to loosen, and then open the cover.

Step 2: Replace the boot media

To replace the boot media, locate it inside the controller and follow the specific sequence of steps.

  1. If you are not already grounded, properly ground yourself.

  2. Remove the boot media:

    Boot media replace graphic
    Callout number 1

    Boot media location

    Callout number 2

    Press down on the blue tab to release the right end of the boot media.

    Callout number 3

    Lift the right end of the boot media up at a slight angle to get a good grip along the sides of the boot media.

    Callout number 4

    Gently pull the left end of the boot media out of its socket.

  3. Install the replacement boot media:

    1. Remove the boot media from its package.

    2. Slide the socket end of the boot media into its socket.

    3. At the opposite end of the boot media, press down and hold the blue tab (in the open position), gently push down on that end of the boot media until it stops, and then release the tab to lock the boot media into place.

Step 3: Reinstall the controller

Reinstall the controller into the chassis, but do not reboot it.

About this task

The following illustration shows the operation of the controller handles (from the left side of a controller) when reinstalling the controller, and can be used as a reference for the rest of the controller reinstallation steps.

controller handle operation to install a controller
Callout number 1

If you rotated the controller handles upright (next to the tabs) to move them out of the way while you serviced the controller, rotate them down to the horizontal position.

Callout number 2

Push the handles to reinsert the controller into the chassis halfway and then, when instructed, push until the controller is fully seated.

Callout number 3

Rotate the handles to the upright position and lock in place with the locking tabs.

Steps
  1. Close the controller cover and turn the thumbscrew clockwise until tightened.

  2. Insert the controller halfway into the chassis.

    Align the rear of the controller with the opening in the chassis, and then gently push the controller using the handles.

    Note Do not completely insert the controller in the chassis until instructed to do so later in this procedure.
  3. Reconnect the cables to the controller; however, do not plug in the power cord to the power supply (PSU) at this time.

    Note Make sure that the console cable is connected to the controller because you want to catch and log the boot sequence later in the boot media replacement procedure when you fully seat the controller in the chassis and it begins to boot.

Step 4: Transfer the boot image to the boot media

The replacement boot media that you installed is without an ONTAP image so you need to transfer an ONTAP image using a USB flash drive.

Before you begin
  • You must have a USB flash drive, formatted to FAT32, with at least 4GB capacity.

  • You must have a copy of the same image version of ONTAP as what the impaired controller was running. You can download the appropriate image from the Downloads section on the NetApp Support Site

    • If NVE is supported, download the image with NetApp Volume Encryption, as indicated in the download button.

    • If NVE is not supported, download the image without NetApp Volume Encryption, as indicated in the download button.

  • You must have a network connection between the node management ports of the controllers (typically the e0M interfaces).

Steps
  1. Download and copy the appropriate service image from the NetApp Support Site to the USB flash drive.

    1. Download the service image from the Downloads link on the page, to your work space on your laptop.

    2. Unzip the service image.

      Note If you are extracting the contents using Windows, do not use WinZip to extract the netboot image. Use another extraction tool, such as 7-Zip or WinRAR.

      The USB flash drive should have the appropriate ONTAP image of what the impaired controller is running.

    3. Remove the USB flash drive from your laptop.

  2. Insert the USB flash drive into the USB-A port on the impaired controller.

    Make sure that you install the USB flash drive in the slot labeled for USB devices, and not in the USB console port.

  3. Fully seat the impaired controller in the chassis:

    1. Firmly push on the handles until the controller meets the midplane and is fully seated.

      Note Do not use excessive force when sliding the controller into the chassis; it could damage the connectors.
      Note The controller boots when fully seated in the chassis. It gets its power from the partner controller.
    2. Rotate the controller handles up and lock in place with the tabs.

  4. Interrupt the boot process by pressing Ctrl-C to stop at the LOADER prompt.

    If you miss this message, press Ctrl-C, select the option to boot to Maintenance mode, and then halt the controller to boot to LOADER.

  5. Set your network connection type at the LOADER prompt:

    • If you are configuring DHCP:

      ifconfig e0M -auto

      Note The target port you configure is the target port you use to communicate with the impaired controller from the healthy controller during var file system restore with a network connection. You can also use the e0M port in this command.
    • If you are configuring manual connections:

      ifconfig e0M -addr=filer_addr -mask=netmask -gw=gateway

      • filer_addr is the IP address of the storage system.

      • netmask is the network mask of the management network that is connected to the HA partner.

      • gateway is the gateway for the network.

      Note Other parameters might be necessary for your interface. You can enter help ifconfig at the firmware prompt for details.
  6. Reconnect the power cord to the power supply (PSU) on the impaired controller.

    Once power is restored to the PSU, the status LED should be green.

    If you are reconnecting a…​ Then…​

    AC PSU

    1. Plug the power cord into the PSU.

    2. Secure the power cord with the power cord retainer.

    DC PSU

    1. Plug the D-SUB DC power cord connector into the PSU.

    2. Tighten the two thumb screws to secure the D-SUB DC power cord connector to the PSU.