Requirements and considerations - AFF C30 and AFF C60
Before replacing the chassis, make sure to review the following requirements and considerations.
Requirements
-
The replacement chassis must be the same model as the impaired chassis. This procedure is for a like-for-like replacement, not for an upgrade.
-
All other components in the storage system must be functioning properly; if not, you must contact NetApp Support before continuing with this procedure.
Considerations
-
The chassis replacement procedure is disruptive. For a two-node cluster, you will have a complete service outage and a partial outage in a multi-node cluster.
-
You can use the chassis replacement procedure with all versions of ONTAP supported by your storage system.
-
The chassis replacement procedure is written with the assumption that you are moving the bezel, drives, any drive blanks, and controllers to the new chassis.
-
If needed, you can turn on the storage system location (blue) LEDs to aid in physically locating the affected storage system. Log into the BMC using SSH and enter the
system location-led on
command.A storage system has three location LEDs: one on the operator display panel and one on each controller. Location LEDs remain illuminated for 30 minutes.
You can turn them off by entering the
system location-led off
command. If you are unsure if the LEDs are on or off, you can check their state by entering thesystem location-led show
command.