Requirements and considerations - AFF C30 and AFF C60
You must review the requirements and considerations for the controller replacement procedure.
Requirements
-
All shelves must be working properly.
-
The healthy controller must be able to take over the controller that is being replaced (referred to in this procedure as the “impaired controller”).
-
You must replace a controller with a controller of the same model type. You cannot upgrade your system by just replacing the controller.
-
You cannot change any drives or shelves as part of this procedure.
-
You must always capture the controller's console output to a text log file.
The console output provides you with a record of the procedure you can use to troubleshoot issues you might encounter during the replacement process.
Considerations
-
It is important that you apply the commands in this procedure to the correct controller:
-
The impaired controller is the controller that is being replaced.
-
The replacement controller is the new controller that is replacing the impaired controller.
-
The healthy controller is the surviving controller.
-
-
If needed, you can turn on the storage system location (blue) LEDs to aid in physically locating the affected storage system. Log into the BMC using SSH and enter the
system location-led on
command.A storage system has three location LEDs: one on the operator display panel and one on each controller. Location LEDs remain illuminated for 30 minutes.
You can turn them off by entering the
system location-led off
command. If you are unsure if the LEDs are on or off, you can check their state by entering thesystem location-led show
command.