Shut down the controller for manual boot media recovery - FAS2820
Shut down or take over the impaired controller.
If your storage system is running ONTAP 9.17.1 or later, use the automated boot recovery procedure. If your system is running an earlier version of ONTAP, you must use the manual boot recovery procedure.
Complete the shutdown of the impaired controller by halting it to the LOADER prompt and capturing the boot environment variables. The LOADER prompt is the safe halted state from which you can replace the boot media.
-
Take the impaired controller to the LOADER prompt:
If the impaired controller displays… Then… The LOADER prompt
Go to Remove controller module.
Waiting for giveback…Press Ctrl-C, and then respond
ywhen prompted.System prompt or password prompt (enter system password)
Take over or halt the impaired controller from the healthy controller:
storage failover takeover -ofnode impaired_node_nameWhen the impaired controller shows Waiting for giveback…, press Ctrl-C, and then respond
y. -
From the LOADER prompt, enter:
printenvto capture all boot environmental variables. Save the output to your log file.This command may not work if the boot device is corrupted or non-functional.
After shutting down the controller, you need to replace the boot media.