Cable an NS224 shelf to your AFF A20 system
Cable your NS224 shelf to your AFF A20 system so that each shelf has two connections to each controller in the HA pair.
You can hot-add one NS224 shelf to an AFF A20 HA pair when additional storage (to the internal shelf) is needed.
-
This procedure assumes that your HA pair has only internal storage (no external shelves) and that you are hot-adding up to one additional shelf.
-
This procedure addresses the following hot-add scenarios:
-
Hot-adding the first shelf to an HA pair with one RoCE-capable I/O module in each controller.
-
Hot-adding the first shelf to an HA pair with two RoCE-capable I/O modules in each controller.
-
-
These systems are compatible with both NS224 shelves with NSM100 modules and NS224 shelves with NSM100B modules. To ensure you cable your controllers to the correct ports, replace the "X" in each diagram with the correct port number for your module:
Module type Port labeling NSM100
"0"
ex. e0a
NSM100B
"1"
ex. e1a
-
If you are hot-adding one shelf using one set of RoCE-capable ports (one RoCE-capable I/O module) in each controller module, and this is the only NS224 shelf in your HA pair, complete the following substeps.
Otherwise, go to the next step.
This step assumes you installed the RoCE-capable I/O module in slot 3. -
Cable shelf NSM A port eXa to controller A slot 3 port a (e3a).
-
Cable shelf NSM A port eXb to controller B slot 3 port b (e3b).
-
Cable shelf NSM B port eXa to controller B slot 3 port a (e3a).
-
Cable shelf NSM B port eXb to controller A slot 3 port b (e3b).
The following illustration shows cabling for one hot-added shelf using one RoCE-capable I/O module in each controller module:
-
-
If you are hot-adding one shelf using two sets of RoCE-capable ports (two RoCE-capable I/O modules) in each controller module, complete the following substeps.
-
Cable NSM A port eXa to controller A slot 3 port a (e3a).
-
Cable NSM A port eXb to controller B slot 1 port b (e1b).
-
Cable NSM B port eXa to controller B slot 3 port a (e3a).
-
Cable NSM B port eXb to controller A slot 1 port b (e1b).
-
The following illustration shows cabling for one hot-added shelf using two RoCE-capable I/O modules in each controller module:
-
Verify that the hot-added shelf is cabled correctly using Active IQ Config Advisor.
If any cabling errors are generated, follow the corrective actions provided.
If you disabled automatic drive assignment as part of the preparation for this procedure, you need to manually assign drive ownership and then reenable automatic drive assignment, if needed. Go to Complete the hot-add.
Otherwise, you are done with the hot-add shelf procedure.