Checking for aggregate relocation failure

Contributors netapp-aherbin netapp-pcarriga netapp-barbe Download PDF of this page

During the procedure, ARL might fail in Stage 2, Stage 3, or Stage 5.

Steps
  1. Enter the following command and examine its output:

    storage aggregate relocation show

    The storage aggregate relocation show command shows you which aggregates were successfully relocated and which ones were not, along with the causes of failure.

  2. Check the console for any EMS messages.

  3. Take one of the following actions:

    • Take the appropriate corrective action, depending on the output of the storage aggregate relocation show command and the output of the EMS message.

    • Force relocation of the aggregate or aggregates by using the override-vetoes option or the override-destination-checks option of the storage aggregate relocation start command.

      For detailed information about the storage aggregate relocation start, override- vetoes, and override-destination-checks options, see the ONTAP 9.8 Commands: Manual Page Reference.