Checking for aggregate relocation failure
During the procedure, ARL might fail in Stage 2, Stage 3, or Stage 5.
-
Enter the following command and examine its output:
storage aggregate relocation show
The
storage aggregate relocation show
command shows you which aggregates were successfully relocated and which ones were not, along with the causes of failure. -
Check the console for any EMS messages.
-
Take one of the following actions:
-
Take the appropriate corrective action, depending on the output of the
storage aggregate relocation show
command and the output of the EMS message. -
Force relocation of the aggregate or aggregates by using the
override-vetoes
option or theoverride-destination-checks
option of thestorage aggregate relocation start
command.For detailed information about the
storage aggregate relocation start
,override- vetoes
, andoverride-destination-checks
options, see the ONTAP 9.8 Commands: Manual Page Reference.
-