简体中文版经机器翻译而成,仅供参考。如与英语版出现任何冲突,应以英语版为准。
完成从双节点无交换机集群到双节点有交换机集群的迁移
按照以下步骤完成从无交换机集群到双节点有交换机集群的迁移。
步骤
-
显示每个节点上每个集群端口所连接的集群交换机端口号:
network device-discovery show显示示例
cluster::*> network device-discovery show Local Discovered Node Port Device Interface Platform ----------- ------ ------------------- ---------------- ---------------- n1 /cdp e4a C1 Ethernet1/7 N3K-C3132Q-V e4e C2 Ethernet1/7 N3K-C3132Q-V n2 /cdp e4a C1 Ethernet1/8 N3K-C3132Q-V e4e C2 Ethernet1/8 N3K-C3132Q-V -
显示已发现和受监控的集群交换机:
ssystem cluster-switch show显示示例
cluster::*> system cluster-switch show Switch Type Address Model --------------------------- ------------------ ---------------- --------------- C1 cluster-network 10.10.1.101 NX3132V Serial Number: FOX000001 Is Monitored: true Reason: Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1) Version Source: CDP C2 cluster-network 10.10.1.102 NX3132V Serial Number: FOX000002 Is Monitored: true Reason: Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1) Version Source: CDP 2 entries were displayed. -
在任何节点上禁用双节点无交换机配置设置:
网络选项 switchless-clusternetwork options switchless-cluster modify -enabled false
-
验证是否已
switchless-cluster选项已禁用。network options switchless-cluster show
-
验证远程集群接口的连接:
ONTAP 9.9.1及更高版本
您可以使用 network interface check cluster-connectivity 命令启动集群连接的可访问性检查、然后显示详细信息:
network interface check cluster-connectivity start 和 network interface check cluster-connectivity show
cluster1::*> network interface check cluster-connectivity start
*注:*请等待几秒钟、然后再运行show命令显示详细信息。
cluster1::*> network interface check cluster-connectivity show
Source Destination Packet
Node Date LIF LIF Loss
------ -------------------------- --------------- ----------------- -----------
n1
3/5/2022 19:21:18 -06:00 n1_clus2 n2_clus1 none
3/5/2022 19:21:20 -06:00 n1_clus2 n2_clus2 none
n2
3/5/2022 19:21:18 -06:00 n2_clus2 n1_clus1 none
3/5/2022 19:21:20 -06:00 n2_clus2 n1_clus2 none
所有ONTAP版本
对于所有ONTAP版本、您还可以使用 cluster ping-cluster -node <name> 用于检查连接的命令:
cluster ping-cluster -node <name>
cluster::*> cluster ping-cluster -node n1
Host is n1
Getting addresses from network interface table...
Cluster n1_clus1 n1 e4a 10.10.0.1
Cluster n1_clus2 n1 e4e 10.10.0.2
Cluster n2_clus1 n2 e4a 10.10.0.3
Cluster n2_clus2 n2 e4e 10.10.0.4
Local = 10.10.0.1 10.10.0.2
Remote = 10.10.0.3 10.10.0.4
Cluster Vserver Id = 4294967293
Ping status:....
Basic connectivity succeeds on 4 path(s)
Basic connectivity fails on 0 path(s)
................
Detected 1500 byte MTU on 32 path(s):
Local 10.10.0.1 to Remote 10.10.0.3
Local 10.10.0.1 to Remote 10.10.0.4
Local 10.10.0.2 to Remote 10.10.0.3
Local 10.10.0.2 to Remote 10.10.0.4
Larger than PMTU communication succeeds on 4 path(s)
RPC status:
1 paths up, 0 paths down (tcp check)
1 paths up, 0 paths down (ucp check)
下一步是什么?
"配置交换机运行状况监控"(英文)