在专用端口上配置ONTAP集群间LUN
您可以在专用端口上配置集群间 LIF 。这样做通常会增加复制流量的可用带宽。
- 
列出集群中的端口: network port show有关的详细信息 network port show,请参见"ONTAP 命令参考"。以下示例显示了中的网络端口 cluster01:cluster01::> network port show Speed (Mbps) Node Port IPspace Broadcast Domain Link MTU Admin/Oper ------ --------- ------------ ---------------- ----- ------- ------------ cluster01-01 e0a Cluster Cluster up 1500 auto/1000 e0b Cluster Cluster up 1500 auto/1000 e0c Default Default up 1500 auto/1000 e0d Default Default up 1500 auto/1000 e0e Default Default up 1500 auto/1000 e0f Default Default up 1500 auto/1000 cluster01-02 e0a Cluster Cluster up 1500 auto/1000 e0b Cluster Cluster up 1500 auto/1000 e0c Default Default up 1500 auto/1000 e0d Default Default up 1500 auto/1000 e0e Default Default up 1500 auto/1000 e0f Default Default up 1500 auto/1000
- 
确定哪些端口可专用于集群间通信: network interface show -fields home-port,curr-port有关的详细信息 network interface show,请参见"ONTAP 命令参考"。以下示例显示了这些端口 e0e和e0f尚未分配的生命周期:cluster01::> network interface show -fields home-port,curr-port vserver lif home-port curr-port ------- -------------------- --------- --------- Cluster cluster01-01_clus1 e0a e0a Cluster cluster01-01_clus2 e0b e0b Cluster cluster01-02_clus1 e0a e0a Cluster cluster01-02_clus2 e0b e0b cluster01 cluster_mgmt e0c e0c cluster01 cluster01-01_mgmt1 e0c e0c cluster01 cluster01-02_mgmt1 e0c e0c
- 
为专用端口创建故障转移组: network interface failover-groups create -vserver system_SVM -failover-group failover_group -targets physical _or_logical_ports以下示例将分配端口 e0e和e0f故障转移组intercluster01在系统SVM上cluster01:cluster01::> network interface failover-groups create -vserver cluster01 -failover-group intercluster01 -targets cluster01-01:e0e,cluster01-01:e0f,cluster01-02:e0e,cluster01-02:e0f 
- 
验证是否已创建故障转移组: network interface failover-groups show有关的详细信息 network interface failover-groups show,请参见"ONTAP 命令参考"。cluster01::> network interface failover-groups show Failover Vserver Group Targets ---------------- ---------------- -------------------------------------------- Cluster Cluster cluster01-01:e0a, cluster01-01:e0b, cluster01-02:e0a, cluster01-02:e0b cluster01 Default cluster01-01:e0c, cluster01-01:e0d, cluster01-02:e0c, cluster01-02:e0d, cluster01-01:e0e, cluster01-01:e0f cluster01-02:e0e, cluster01-02:e0f intercluster01 cluster01-01:e0e, cluster01-01:e0f cluster01-02:e0e, cluster01-02:e0f
- 
在系统 SVM 上创建集群间 LIF 并将其分配给故障转移组。 选项 Description - 
在 ONTAP 9.6 及更高版本中: * 
 network interface create -vserver system_SVM -lif LIF_name -service-policy default-intercluster -home-node node -home- port port -address port_IP -netmask netmask -failover-group failover_group- 
在 ONTAP 9.5 及更早版本中: * 
 network interface create -vserver system_SVM -lif LIF_name -role intercluster -home-node node -home-port port -address port_IP -netmask netmask -failover-group failover_group有关的详细信息 network interface create,请参见"ONTAP 命令参考"。以下示例将创建集群间生命周期 cluster01_icl01和cluster01_icl02在故障转移组中intercluster01:cluster01::> network interface create -vserver cluster01 -lif cluster01_icl01 -service- policy default-intercluster -home-node cluster01-01 -home-port e0e -address 192.168.1.201 -netmask 255.255.255.0 -failover-group intercluster01 cluster01::> network interface create -vserver cluster01 -lif cluster01_icl02 -service- policy default-intercluster -home-node cluster01-02 -home-port e0e -address 192.168.1.202 -netmask 255.255.255.0 -failover-group intercluster01 
- 
- 
验证是否已创建集群间 LIF : 选项 Description - 
在 ONTAP 9.6 及更高版本中: * 
 network interface show -service-policy default-intercluster- 
在 ONTAP 9.5 及更早版本中: * 
 network interface show -role intercluster有关的详细信息 network interface show,请参见"ONTAP 命令参考"。cluster01::> network interface show -service-policy default-intercluster Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home ----------- ---------- ---------- ------------------ ------------- ------- ---- cluster01 cluster01_icl01 up/up 192.168.1.201/24 cluster01-01 e0e true cluster01_icl02 up/up 192.168.1.202/24 cluster01-02 e0f true
- 
- 
验证集群间 LIF 是否冗余: 选项 Description - 
在 ONTAP 9.6 及更高版本中: * 
 network interface show -service-policy default-intercluster -failover- 
在 ONTAP 9.5 及更早版本中: * 
 network interface show -role intercluster -failover有关的详细信息 network interface show,请参见"ONTAP 命令参考"。以下示例显示了集群间的生命周期 cluster01_icl01和cluster01_icl02在SVM上e0e端口将故障转移到e0f端口。cluster01::> network interface show -service-policy default-intercluster –failover Logical Home Failover Failover Vserver Interface Node:Port Policy Group -------- --------------- --------------------- --------------- -------- cluster01 cluster01_icl01 cluster01-01:e0e local-only intercluster01 Failover Targets: cluster01-01:e0e, cluster01-01:e0f cluster01_icl02 cluster01-02:e0e local-only intercluster01 Failover Targets: cluster01-02:e0e, cluster01-02:e0f
- 
 PDF
PDF